E690001 “ CVS is not installed ” “ 未设置 CVS 。 ” [Cause] CVS is not installed on the machine. [Treatment] ‧If CVS is actu ally install ed on your machine, please enable t he uni t in the MS parameter option. E690002 “ Impo…
‧If the error still occurs even after all the treatments above were taken place, please contact our
technical service dept. for information.
E651008 “Although the motor stopped, encoder does not stop”
“马达已经停止,但编译器没有停止。”
[Cause]
It is confirmed that the motor of the Auto. PWB Width Alignment control has stopped but not the
encoder.
‧The Auto. PWB Alignment control unit is broken.
[Treatment]
‧Please examine the Auto. PWB Width Alignment control with Manual control.
‧Please turn off the power supply of your machine and re-boot it. If the error occurs even after the
re-boot, please contact with our technical service dept. for information.
E651009 “An error occurred when starting the motor”
“起动马达时发生错误。”
[Cause]
An error occurred when the motor of the Auto. PWB Width Alignment control got started.
[Treatment]
‧Please turn off the power supply of your machine and re-boot it. If the error occurs even after the
re-boot, please contact with our technical service dept. for information.
E651010 “An error occurred while waiting for the motor to stop”
“等待马达停止时发生错误。”
[Cause]
An error occurred while the motor of the Auto. PWB Width Alignment control was moving.
[Treatment]
‧Please turn off the power supply of your machine and re-boot it. If the error occurs even after the
re-boot, please contact with our technical service dept. for information.
E651011 “An error occurred while reading ORIGIN sensor in”
“读取原点传感器时发生错误。”
[Cause]
An error occurred while reading the ORIGIN sensor of the Auto. PWB Width Alignment control in.
[Treatment]
‧ Please turn off the power supply of your machine and re-boot it. If the error occurs even after the
re-boot, please contact with our technical service dept. for information.
E651012 “The motor is not stopping.”
“马达尚未停止”
E690001 “CVS is not installed”
“未设置 CVS。”
[Cause]
CVS is not installed on the machine.
[Treatment]
‧If CVS is actually installed on your machine, please enable the unit in the MS parameter option.
E690002 “Impossible to switch to Resistance Measurement mode since the probe has not shut down. | Please
shut the probe down then try again”
“因探针没有被关闭,不能切换到测定电阻模式。|请关闭探针后再执行。”
[Cause]
In order to set measurement mode to the Resistance mode, the probe has to be closed to adjust
resistance.
‧The probe is not closed.
[Treatment]
‧Please close the probe then set the measurement mode.
E690003 “Impossible to switch to Condenser Measurement mode since the probe has not shut down. | Please
shut the probe down then try again”
“因探针没有被打开,不能切换到测定电容模式。|请打开探针后再执行。”
[Cause]
In order to set measurement mode to the Condenser mode, the probe has to be closed to adjust
capacity.
‧The probe is not closed.
[Treatment]
‧Please close the probe then set the measurement mode.
E690004 “The measurement mode is not correct”
“测定模式不正确。”
[Cause]
The measurement mode parameter is not correct.
[Treatment]
‧Please re-start the application.
‧Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please contact our technical
service dept. for information.
E690005 “Parameter to control probe is not correct”
“控制探针参数不正确。”
[Cause]
The parameter to control probe is not correct.
[Treatment]
‧Please re-start the application.
‧Please re-install or version-up the application.
‧If the error occurs even after the treatments above were performed, please contact our technical
service dept. for information.
E690006 “Probe has to be shut down to measure resistance. | Please shut probe then try again”
“不关闭探针,就不能测定电阻。|请关闭探针后执行。”
[Cause]
In order to measurement resistance, the probe has to be closed.
The probe is not closed.
‧The probe is not closed.
[Treatment]
‧Please close the probe then measure the resistance.
E690007 “Probe has to be shut down to measure condenser. | Please shut probe then try again”
“不关闭探针,就不能测定电容。|请关闭探针后执行。”
[Cause]
In order to measurement condenser capacity, the probe has to be closed.
The probe is not closed.
‧The probe is not closed.
[Treatment]
‧Please close the probe then measure the condenser capacity.
E690008 “Diode measurement is not available unless probe shuts down. | Please shut probe then try again”
“不关闭探针,就不能测定电流方向。|请关闭探针后执行。”
[Cause]
The probe has to be closed to measure diode polarity.
‧The probe is not closed.
[Treatment]
‧Please close the probe then try the measurement.
E690009 “The measurement is impossible since measurement mode is not set to Resistance measurement. |
Please switch to the Resistance measurement mode then try again”
“因为不是测定电阻模式,不能测定电阻。|请切换到测定电阻模式后执行。”
[Cause]
In order to measure resistance, the measurement mode has to be the Resistance measurement mode.
‧Measurement mode is not set to the Resistance measurement mode.
[Treatment]