Q290503 “ The mark has already been regis tered. Do you overwrite? ” “ 已经存在标记,是否覆盖保存? ” [Cause] There is a mark data left, which was registered before. You are asked if to overwrite the data. [Treatment] If you want to o…

100%1 / 464
E290026 There is no MTS stacker.”
MTS 托盘存储箱不存在。
E290027 MTS failed in drawing out the tray.”
MTS 取出托盘失败。
E290028 MTS device is set in unused by the setup.”
在设置中,MTS 装置没有被选用。
E290029 Transmit error of template data. Please teaching try again.”
模板数据传输发生错误。请再次示教修改。
E290030 The bank mark recognition error (MTS). | Teaching is aborted.”
识别台架标记出错(MTS)| 停止运行
Q290500 It is not possible to move to specified position with this device. | Please push 'No' when you
discontinue 'Yes' when the teaching is started from the current position
这个设备不能移到指定坐标上。|从当前位置开始示教,请按[]﹔停止,请按[]
[Cause]
You can not move to the previously set coordinates with the device selected by HOD. You are asked
if to resume the teaching from the current position.
[Treatment]
If you want to continue the process, press Yes. If not, press No.
Q290501 The teaching operation is executed. Please confirm safety. | Please push 'No' when you discontinue
'Yes' when executing this
运行示教操作,请注意安全。|执行,请按[]﹔停止,请按[]
[Cause]
You are asked if to perform the safety check since this operation takes axis traveling.
[Treatment]
If you want to continue the process, press 'Yes'. If not, press 'No'.
Q290502 The position cannot be corrected. | Please push 'No' when you discontinue 'Yes' when correction is
not considered and teaching is executed
不能运行坐标校正。|不考虑校正继续运行示教,请按[]﹔停止,请按[]
[Cause]
You need to correct the coordinates in order to teach the coordinates to the machine accurately, but
the Mark recognition that is necessary for the coordinate correction failed for some reason. You are
asked if to continue the teaching although the accurate teaching cannot be expected if you continue
the process..
[Treatment]
If you want to continue the process, press 'Yes'. If not, press 'No'.
Q290503 The mark has already been registered. Do you overwrite?
已经存在标记,是否覆盖保存?
[Cause]
There is a mark data left, which was registered before. You are asked if to overwrite the data.
[Treatment]
If you want to overwrite the data, press 'Yes'. If not, press 'No'.
E291000 Conveyor already operated, it is not possible to operation
因为正在运行传送操作,所以不能执行。
[Cause]
The conveyor has already been in operation.
[Treatment]
Please wait for a while and try again.
E291001 The origin point return is non-completion. | Please operate again after completing the origin point
return
没有执行返回原点。|请执行返回原点后,再次操作。
[Cause]
Home returning has not been complete yet.
[Treatment]
Please press the ORIGIN button to perform the Home returning, and try again.
E291002 The axis cannot be moved to escape point. | Execution is aborted
轴不能移到等待位置。|停止运行。
[Cause]
Failed to move the axis to the escape point.
[Treatment]
Please check and see if the axis works properly with Manual control.
E291003 The conveyor cannot be moved. | Execution is aborted
不能执行传送。|停止运行。
[Cause]
The conveyor did not work for some reason.
[Treatment]
Please check and see if the conveyor works properly with Manual control.
E291004 The conveyor became a time-out. | Execution is aborted
传送超过时间。|停止运行。
[Cause]
PWB conveying had a time-out error.
[Treatment]
Please check and see if the conveyor works properly with Manual control.
E291005 The axis cannot be moved. | Execution is aborted
轴不能移动。|停止运行。
[Cause]
The axis could not move for some reason.
[Treatment]
Please check and see if the axis works properly with Manual control.
E291006 The BOC mark data is not set. | Operation is aborted
没有设置 BOC 标记数据。|停止运行。
[Cause]
BOC mark was not set in the Board data or the Board data is incomplete.
[Treatment]
Please set and complete the board data.
E291007 The OCC device is set in unused by the setup
在设置中,OCC 装置没有被选用。
[Cause]
The OCC device is set to not use in Setup.
[Treatment]
If the device is available, set it to use in Setup. If not, this operation cannot be executed.
E291008 Value is mistake
设置数据有差错。
[Cause]
The value is wrong when you hit the Enter key to define it.
[Treatment]
Please check the entered value.
E291009 Value out of range
设置数据超出范围。
[Cause]
The value when you hit the Enter key to define it exceeded the input range.
[Treatment]
Please enter a value which is within the input range.
E291010 Conveyor margin out of range. It is not possible to operation
因传送边界超出范围,不能进行操作。
[Cause]
Failed to take the value in as a margin since there is a too much difference between the conveyor