JUKI贴片机错误代码集合.pdf - 第230页
A nozzle returning was requested while the vacuum of the left h ead2 is sti ll ON. There is a possibility that a component is being picked by the head. 左 Head2 的真空被启动的状态下要放 回吸嘴。吸嘴上可能附有组件。 [Treatment] Please take the comp…
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610301 “An error occurred when ComRes response receive”
“接受 COMRES 应答出错。”
[Cause]
Response reception of Command-Response type failed. This is an error that occurred during the data
communication in the machine.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧ If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610302 “Z movement place parameter is not correct.”
“Z 移动地点参数不正确。”
E610303 “T movement place parameter is not correct.”
“T 移动地点参数不正确。”
E610304 “The timeout occurred in the waiting for an event.”
“发生事件等待错误。”
E610305 “The error occurred in event issue.”
“发生事件发行错误。”
E610400 “Vacuum of L1 head has been on”
“L1 Head 真空被打开。”
[Cause]
A nozzle returning was requested while the vacuum of the left head1 is still ON. There is a possibility
that a component is being picked by the head.
左 Head1 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610401 “Vacuum of L2 head has been on”
“L2 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the left head2 is still ON. There is a possibility
that a component is being picked by the head.
左 Head2 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610402 “Vacuum of L3 head has been on”
“L3 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the left head3 is still ON. There is a possibility
that a component is being picked by the head.
左 Head3 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610403 “Vacuum of L4 head has been on”
“L4 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the left head4 is still ON. There is a possibility
that a component is being picked by the head.
左 Head4 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610404 “Vacuum of R1 head has been on”
“R1 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the right head1 is still ON. There is a
possibility that a component is being picked by the head.
右 Head1 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610405 “Vacuum of R2 head has been on”
“R2 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the right head2 is still ON. There is a
possibility that a component is being picked by the head.
右 Head2 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610406 “Vacuum of R3 head has been on”
“R3 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the right head3 is still ON. There is a
possibility that a component is being picked by the head.
右 Head3 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610407 “Vacuum of R4 head has been on”
“R4 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the right head4 is still ON. There is a
possibility that a component is being picked by the head.
右 Head4 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610408 “The specified nozzle has been installed”
“指定吸嘴已经被安装。”
[Cause]
The nozzle requested to be installed has been already loaded on the head. The request of the nozzle
installation is not necessary.
指定的吸嘴已经都安装在 Head 上,没有必要再安装。
[Treatment]
This process can not be performed.
E611015 “An error occurred when starting LZ1 axis movement.”
“LZ1 轴开始移动时发生错误。”
E612015 “An error occurred when starting LZ2 axis movement.”
“LZ2 轴开始移动时发生错误。”