JUKI贴片机错误代码集合.pdf - 第132页

E510016 “ Failed in t he reception of the response from the Trans-driver ” “ 接收传送驱动器应答失败。 ” [Cause] The software did not g et started properly. [Treatment] Please turn off the power supply of t he machine and reboot it. …

100%1 / 464
E510010 Failed in the mail check
检查邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510011 Failed in the mail reception
接收邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510012 Failed in the opening of the mail of the production-control
打开生产管理邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510013 Failed in the transmission of the mail to the production-control
往生产管理发送邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510014 Failed in the opening of the command of the Trans-driver
打开传送驱动命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510015 Failed in the transmission of the command to the Trans-driver
往传送驱动器发送命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510016 Failed in the reception of the response from the Trans-driver
接收传送驱动器应答失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510017 Failed in the opening of the command of the sub-scheduler
打开次调度程序失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510018 Failed in the transmission of the command to the sub-scheduler
往次调度程序发送命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510019 Failed in the reception of the response from the sub-scheduler
接收次调度程序应答失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510020 Failed in the opening of the command of the XY-robot
打开 XY-Robot 命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510021 Failed in the transmission of the command to the XY-robot
XY-Robot 发送命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510022 Failed in the reception of the response from the XY-robot
接收 XY-Robot 应答失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510023 It is algorithm change error.”
变更测量方法(Algorithm)失败。
E510024 The part abandonment is abnormal.”
废弃组件失败。
E510025 It is image taking picture error.”
图像的摄像发生错误。
E510026 All circuit bad mark was detected.”
发现全电路的坏板标记。
E510027 It is a trans-driver system error.”
传送驱动系统发生错误。
E510028 Since production control is unusual, production is forced to terminate.”
因生产控制发生错误,强行退出生产。
E510101 The error occurred by the Tombstone
芯片站立出错。
E510102 The error occurred by the Component fall
发生组件脱落。
E510103 The error occurred by the Verify.”
发生数值检查错误。
E510104 Failed in the Illrgal component picking(MTC).”
组件吸取(MTC)出错。
E510105 Failed in the Component direction.”
组件方向出错。
E510106 The error occurred by the Feeder pitch gap.”
送料间距出错。
E510107 Failed in the Unplaced