[Cause] Failed to initialize a vision devi ce driver internally. Device manager did not g et started properly. [Treatment] Please re-boot your machine. E630010 “ There is no empty space in t he Vision Resource Semaphore …

100%1 / 464
E620054 Feeder sensor stopped.Servo is in the free state.”
因传送带浮动而停止。未使用伺服。
I620055 Servo is in the free state.”
未使用发生
E620056 Servo free error.”
关闭发生错误。
E620057 Air pressure sensor alarm. Ignore?
发现气压下降,是否忽略?
E620058 The power failure was detected.|Re-starting of a system is required.|Please re-switch on a power
supply after a shutdown.”
检测出停电,请关闭电源后,重新起动
E620059 Communication error of Axis occurred.”
轴通讯出错。
E620060 DTS supply key.”
DTS 供给组件按钮被按下。
E620061 XH driver alarmed.”
XH 轴驱动警报。
E630001 ViLib Entry : Failed in initializing.”
ViLib 错误:|ViLibEntry 初始化失败
[Cause]
You tried to get several vision device drivers started at one time.
More than one application are running.
[Treatment]
Please re-start the application.
E630002 ViLib Entry : UN-initializing error occurred
ViLib 错误:|未做 ViLibEntry 初始化, 调用 ViLibEntry
[Cause]
You tried to use a vision device driver without initializing it.
More than one application are running.
[Treatment]
Please re-start the application.
E630003 ViLib Thread: Driver Failed to get Thread starated
ViLib 错误:|ViLib 起动线程失
[Cause]
Failed to initialize a vision device driver internally.
Device manager did not get started properly.
[Treatment]
Please re-boot your machine.
E630010 There is no empty space in the Vision Resource Semaphore
ViLib 错误:|没有信号登录
[Cause]
A vision device driver did not get started properly.
You tried to get several vision device drivers started at one time.
[Treatment]
Please re-boot your machine.
E630011 ViLib Thread: Failed in registration of bass interrupting
ViLib 错误:|总线中断的登录失败
[Cause]
A vision device driver did not get started properly.
You tried to get several vision device drivers started at one time.
[Treatment]
Please re-boot your machine.
E630012 ViLib Thread: Failed to open the serial port.”
ViLib 错误:|打开串行端口失败。
[Cause]
COM port does not return any response.
Another application is using COM port.
[Treatment]
Please re-start the application.
E630050 ViLib Entry: IPC Send Error(Entry->Thread) occurred
ViLib 错误:|IPC 发送信息包错误(Entry->DriverThread)
[Cause]
Failed in IPC transmission to the vision device driver.
The vision device driver is HOLT.
[Treatment]
Please re-boot your machine.
E630051 ViLib Entry: IPC Receive Error(Entry<-Thread) occurred
ViLib 错误:|IPC 接收信息包错误(Entry<-DriverThread)
[Cause]
Failed in IPC reception from the vision device driver.
The vision device driver is HOLT.
[Treatment]
Please re-boot your machine.
E630052 ViLib Entry: Error Execute Undefined Command
ViLib 错误:|发现未定义命令代码
[Cause]
You tried to execute an undefined vision command.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
E630053 ViLib Thread: Undefined ViOS event is requested
ViLib 错误:|发现未定义 OS 事件要求
[Cause]
You tried to issue an undefined vision event request.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
E630054 ViLibError:| Command handshake error (skipped ACK).”
ViLib 错误:|命令同步交换错误(Skipped ACK)
E630073 Vision Data: Ball patter has not been set yet
ViLib 错误:|没有设置球图案
[Cause]
There is no ball patter data in the vision data.
[Treatment]
Please examine the production program.
Please re-load the production program.
E630074 Camera scale has not been set yet
ViLib 错误:|没有设置摄像机缩放比
[Cause]
There are some items that have not been set yet in the Camera scaling in MS Parameter.
[Treatment]
Please examine the Camera scaling in MS Parameter.