JUKI贴片机错误代码集合.pdf - 第117页

“ 前一次结束生产时的生产站台 (%s) 和 这一次指定的生产站台 (%s) 不同, | 将丢失一侧站台的 继续生产情报,是否继续生产? “ W503404 “ The production execution station (%s) speci fied the production execution station (%s) of the las t time end at this time is different.|Is …

100%1 / 464
[Cause]
This message appears if the current sequence and the previous sequence are different from each other
when resuming the production.
Sequence
‧Input order
‧Optimization order
[Treatment]
OK button : Starts the production with the sequence being different from the previous one. There
is a possibility that PWBs will be incomplete.
Cancel button : Will have you back to the status that is before pressing START key.
E503401 The Production start No. that is currently set(%s) is larger than the one(Left: %s Right: %s) of
when the production got suspended illegally last time. Would you like to start the production though
the PWB may become incomplete?
当前设置的生产开始号(%s) |大于比前一次结束生产时的开始号(:%s :%s)|可能发生
贴片遗漏现象,是否开始继续生产?
[Cause]
This message appears if current production start No. is larger than the one of when the production got
suspended illegally last time when resuming the production.
[Treatment]
OK button : Starts the production with current production start No. (Placement data index) being
larger than the previous one. There is a possibility that PWBs will be incomplete.
Cancel button : Will have you back to the status that is before pressing START key.
E503402 The Production stop No. that is currently set (%s) us smaller than the one (Left: %s Right: %s) of
when the production got suspended illegally last time. Would you like to start the production though
the PWB may become incomplete?
当前设置的生产结束号(%s) |小于比前一次结束生产时的结束号(:%s :%s)|可能发生
贴片遗漏现象,是否开始继续生产?
[Cause]
This message appears if current production stop No. is smaller than the one of when the production
got suspended illegally last time when resuming the production.
[Treatment]
OK button : Starts the production with current production stop No. (Placement data index) being
smaller than the previous one. There is a possibility that PWBs will be incomplete.
Cancel button : Will have you back to the status that is before pressing START key.
W503403 The product exeut station (%s) specified the product exect station (%s) of the last time end at this
time is different.|Does resume the product begin though continuance product information on the
station in one side is lost?
前一次结束生产时的生产站台(%s)这一次指定的生产站台(%s)不同,|将丢失一侧站台的
继续生产情报,是否继续生产?
W503404 The production execution station (%s) specified the production execution station (%s) of the last
time end at this time is different.|Is production started though the continuance production cannot be
done at this time?
前一次结束生产时的生产站台(%s)和这一次指定的生产站台(%s)不同,|这次不能进行继
续生产,是否开始生产?
W503405 The production mode (%s) set at this time as the production mode (%s) when ending last time is
different according to using unused of the unit.|Is production started though the continuance
production cannot be done at this time?
前一次结束生产时的生产模式(%s)这一次生产模式(%s),因单元的使用情况不同而不
同。|这次不能进行继续生产,是否开始生产?
W503406 The sequence(%s) you selected is different from the one(%s) of when the production got suspended
last time.|Is production started though the continuance production cannot be done at this time?
前一次结束生产时的顺序(%s)和这一次选择的顺序(%s)不一样。|这次不能进行继续生产,
是否开始生产?
W503407 The prod. start end position where it is set to end last time at the prod. start end pos. and this time
is different.|Is production started though the continuance production cannot be done at this time?
前一次结束生产时的生产开始和结束位置与这一次设置的生产开始和结束位置不同,|
次不能进行继续生产,是否开始生产
W503408 Differing the Place station of the last time end and the Place station of this time exists.|Is
production started though the continuance production cannot be done at this time?
前一次结束生产时的贴片站台与这一次贴片站台不同。|这次不能进行继续生产,是否开
始生产?
E503500 No completion change plan. Please use Feeder Bank
未完成替换准备,|请使用送料器台架
[Cause]
This message appears if Non-stop production is set in the Operation Option and the feeder bank on
the front side is descending down when reading a file in.
[Treatment]
Please have the feeder bank ascend.
W503501 There is no trolley option in the setup data.|The non-stop operation is selected.”
在设置数据中,交换台选项为无效状态,|不间断运行被选用。
W503502 There is no feeder float sensor in the setup data.|The non-stop operation is selected.”
在设置数据中,传送带浮动选项为无效状态,|不间断运行被选用。
W503600 The input data is over the Input range(%s).|Would you like to set the data?
输入的数据超过输入范围,|是否继续设置?
W503601 The input data is changed.|Is the data setting ended?
数据正在被更新,|是否结束数据更新
W503700 There is no Data.|Please select the area where the data is displayed.”
没有数据,|请选择数据。
W503800 The head is specified for an unused head by the place data.|The input order production cannot be
executed.”
在贴片数据上,指定了不使用 Head|不能进行输入顺生产。
W503801 Right or Left OCC is unused.|(There is both head specification in the production program.)|The
input order production cannot be executed.”
不使用或左或右 OCC|(生产程序内已经指定两个 Head)|不能进行输入顺生产。
W503802 Left OCC is unused.|(There is left head specification in the production program.)|The input order
production cannot be executed.”
不使用左 OCC|(生产程序内已经指定左 Head)|不能进行输入顺生产。
W503803 Right OCC is unused.|(There is right head specification in the production program.)|The input order
production cannot be executed.”
不使用左 OCC|(生产程序内已经指定左 Head)|不能进行输入顺生产。
W503804 There is a station which it is a setup and is unused.|(There is both head specification in the
production program.)|The input order production cannot be executed.”
在设置中存在不使用站台|(生产程序内已经指定两个 Head)|不能进行输入顺生产。
W503805 It is a setup and a left station is unused.|(There is left head specification in the production
program.)|The input order production cannot be executed.”
在设置中,左站台处于不使用状态|(生产程序内已经指定左 Head)|不能进行输入顺生产。
W503806 It is a setup and a right station is unused.|(There is right head specification in the production
program.)|The input order production cannot be executed.”
在设置中,右站台处于不使用状态|(生产程序内已经指定右 Head)|不能进行输入顺生产。
W503810 It is the data which the exit side station installs earlier than the entrance side station.|The input
order production cannot be executed.”
存在出口侧站台比入口侧站台先进行贴片的数据,|不能进行输入顺生产。
W503820 There is no adjustment in setting the pick position and the use unit.|The input order production