JUKI贴片机错误代码集合.pdf - 第101页
“ 发现 %s 上传 送带浮动。 ” [Cause] A matter that may interrupt t he Feeder floatation sensor occurr ed. where the matter occurred. ‧On the front side ‧On the rear side ‧On both sides [Treatment] Please remove the obstruction tha…
cannot be executed.”
“只有左边站台,存在吸取位置,|左边站台上没有可用吸嘴,|不能进行生产。”
E500266 “The adsorption position is only at a left station.|The use nozzle is not at a right station.|Production
cannot be executed.”
“只有右边站台,存在吸取位置,|右边站台上没有可用吸嘴,|不能进行生产。”
E500270 “Smaller layer than the layer of the entrance side station exists in the installing data of the exit side
station.”
“出口侧站台的贴片数据上,存在比入口侧站台小的阶层。”
E500271 “It is the data which the exit side station installs earlier than the entrance side station.|Production
cannot be executed.”
“出口侧站台存在比入口侧站台先贴片的数据,|不能进行生产。”
E500272 “There is no adjustment in setting the adsorption position and the use unit.|Production cannot be
executed.”
“吸取位置或使用单元的设置不一致,|不能进行生产。”
E500300 “Origin retrieval has not yet been completed”
“尚未完成返回原点。”
[Cause]
You tried to resume the production without completing the Origin retrieval after an unexpected stop
such as Emergency stop.
[Treatment]
Please perform the Origin retrieval by pressing the ORIGIN button on the operation panel.
E500301 “Servo is turned OFF”
“伺服被关闭。”
[Cause]
The production can not be executed since the Servo is free.
[Treatment]
Please perform the Origin retrieval by pressing the ORIGIN button on the operation panel.
E500302 “Air was down”
“气压被下降。”
[Cause]
The air pressure is getting down.
[Treatment]
Please adjust the air pressure to its original level.
E500303 “Detected %s feeder float”
“发现%s 上传送带浮动。”
[Cause]
A matter that may interrupt the Feeder floatation sensor occurred.
where the matter occurred.
‧On the front side
‧On the rear side
‧On both sides
[Treatment]
Please remove the obstruction that may be interrupting the sensor.
E500304 “The servo power supply does not enter for the cover opening. |Please close the cover.”
“因机盖被打开,不能启动起动伺服。|请关闭机盖。”
E500305 “The servo power supply does not enter for the bank descent. |Please raise the bank.”
“因送料器台架被下降,不能启动伺服。|请台升送料器台架。”
E500400 “Machine was gone to abnormal state”
“机器有些不正常。”
E500401 “Input order Simple Opt. Error <%s>“ “建立进度表数据出错 |<%s>“
[Cause]
An error occurred while optimizing the pick positions by input orders.
The details of the error
1. There is no component corresponding to the feeder.
2. The head can not travel to the feeder/MTC position.
3. The head can not travel to the holder/MTS position.
4. There is no head available to place the component.
5. There is no head that meets the centering type.
6. An internal error of the Input order Simple Opt. Error process.
[Treatment]
1 and 6 are a program error. Please make a note of the cause of the error and the error code, then
contact our technical service Dept. for information.
In case of 2, 3, and 4, please go to the Production Program Editor and see the specified head(s) in the
Placement data.
In case of 5, please go to the Production Program Editor and see the centering type in the Component
data.
E500402 “An error occurred in the checking prior to the production. |<%s>“
“在生产开始之前的检测中发生错误。|<%s>“
E500403 “Machine was gone to abnormal state.|The process gets discontinued. |Please put the power supply
again.”
“机器发生异常,请退出生产,关闭系统后,重新启动。”
E500500 “Teaching can not be executed”
“不能执行示教。”
[Cause]
You are trying to teach unexecuted data to the machine.
Unexecuted data:
Data except ref. circuit in the Placement position teaching.
Components except tray component in the Pick position teaching.
When multiple heads are working at the same time.
[Treatment]
You can not perform a teaching with the current status. Please go on the process.
E500501 “The selected device can not be used”
“不能使用被选设备。”
[Cause]
You selected a device not available.
[Treatment]
Please change devices to use.
E500502 “With the selected device, it is impossible to move to the aimed position”
“被选设备不能移到目的位置。”
[Cause]
You can not move to the specified position with the selected device.
[Treatment]
Please select another device.
E500503 “Standard Pin position illegal. Correct coordinates can not acquire”
“基准针位置不对。|不能取得正确坐标。”
[Cause]
The position of the reference pin is not correct.
[Treatment]
In the Setup, please teach the positions of the reference pin and follower pin to the machine.
E500600 “YC table error. Code : %d”
“Yc 支撑台出错。|代码 : %d”
E500601 “Axis movement error. Code : %d”
“轴通讯错误”