JUKI贴片机错误代码集合.pdf - 第53页
Please check and see if the con ve yor works properly wi th Manual control. E291005 “ The axis cannot be moved. | Executi on is aborted ” “ 轴不能移动。 | 停止运行。 ” [Cause] The axis could not move for some reason. [Treatment] Pl…
Q290503 “The mark has already been registered. Do you overwrite?”
“已经存在标记,是否覆盖保存?”
[Cause]
There is a mark data left, which was registered before. You are asked if to overwrite the data.
[Treatment]
If you want to overwrite the data, press 'Yes'. If not, press 'No'.
E291000 “Conveyor already operated, it is not possible to operation”
“因为正在运行传送操作,所以不能执行。”
[Cause]
The conveyor has already been in operation.
[Treatment]
Please wait for a while and try again.
E291001 “The origin point return is non-completion. | Please operate again after completing the origin point
return”
“没有执行返回原点。|请执行返回原点后,再次操作。”
[Cause]
Home returning has not been complete yet.
[Treatment]
Please press the ORIGIN button to perform the Home returning, and try again.
E291002 “The axis cannot be moved to escape point. | Execution is aborted”
“轴不能移到等待位置。|停止运行。”
[Cause]
Failed to move the axis to the escape point.
[Treatment]
Please check and see if the axis works properly with Manual control.
E291003 “The conveyor cannot be moved. | Execution is aborted”
“不能执行传送。|停止运行。”
[Cause]
The conveyor did not work for some reason.
[Treatment]
Please check and see if the conveyor works properly with Manual control.
E291004 “The conveyor became a time-out. | Execution is aborted”
“传送超过时间。|停止运行。”
[Cause]
PWB conveying had a time-out error.
[Treatment]
Please check and see if the conveyor works properly with Manual control.
E291005 “The axis cannot be moved. | Execution is aborted”
“轴不能移动。|停止运行。”
[Cause]
The axis could not move for some reason.
[Treatment]
Please check and see if the axis works properly with Manual control.
E291006 “The BOC mark data is not set. | Operation is aborted”
“没有设置 BOC 标记数据。|停止运行。”
[Cause]
BOC mark was not set in the Board data or the Board data is incomplete.
[Treatment]
Please set and complete the board data.
E291007 “The OCC device is set in unused by the setup”
“在设置中,OCC 装置没有被选用。”
[Cause]
The OCC device is set to “not use” in Setup.
[Treatment]
If the device is available, set it to “use” in Setup. If not, this operation cannot be executed.
E291008 “Value is mistake”
“设置数据有差错。”
[Cause]
The value is wrong when you hit the Enter key to define it.
[Treatment]
Please check the entered value.
E291009 “Value out of range”
“设置数据超出范围。”
[Cause]
The value when you hit the Enter key to define it exceeded the input range.
[Treatment]
Please enter a value which is within the input range.
E291010 “Conveyor margin out of range. It is not possible to operation”
“因传送边界超出范围,不能进行操作。”
[Cause]
Failed to take the value in as a margin since there is a too much difference between the conveyor
width and the board size in Y direction.
[Treatment]
Please adjust the difference between the conveyor width and the board size in Y direction with a hand
knob, then try again.
E291011 “Cannot move conveyor”
“不能移动传送幅宽。”
[Cause]
This error occurs when the conveyor width cannot be adjusted for some reason. There is a possibility
that an obstruction is being detected by a sensor on the conveyor.
[Treatment]
Please make sure that there is no obstruction to be detected by sensors between the current position
and the destination.
E291012 “The BOC mark recognition error [Circuit : %d / %d point]”
“识别 BOC 标记发生错误 [ 电路号 : %d / %d 点 ]”
[Cause]
VCS could not recognize the BOC mark(s).
1): Circuit number
2): The Xth BOC mark.
[Treatment]
There is a possibility that the BOC mark(s) could not be taught to the machine properly.
E291013 “The area sensor was detected. Execution is aborted”
“发现位置错误。结束运行。”
[Cause]
The process got forcibly aborted since the area sensor detected something.
[Treatment]
Please remove the factor that was detected by the sensor.
E291014 “Emergency stopped. Execution is aborted”
“紧急停止状态。结束运行。”
[Cause]
The process got forcibly aborted since the Emergency STOP occurred.
[Treatment.]
Please remove the cause of the Emergency STOP.
E291015 “PWB exist in the entry side center buffer. | Please execute retry after ejection”
“入口缓冲处存在基板。|搬出入口处基板后,再次执行。”
[Cause]
PWB loading did not succeed since a PWB is staying on the inlet side of the buffer.