JUKI贴片机错误代码集合.pdf - 第64页
device selected by HOD. [Treatment] Please reselect a device available. E301018 “ Selected device is not installed . | Please reselect other devic e on HOD ” “ 被选设备尚未安装。 | 请重新选择其它 设备。 ” [Cause] Since the device selected …
E301011 “An error occurred while installing nozzles.”
“安装吸嘴发生错误。”
E301012 “An error occurred while measuring nozzle height by Laser”
“激光测定吸嘴高度发生错误。”
[Cause]
An error occurred during the laser height measurement by laser.
[Treatment]
Something might be wrong with Laser alignment. Please check it.
E301014 “Failure has occurred during measurement of nozzle shape by laser. | Laser status: %3d”
“激光测定吸嘴外形发生错误。| 激光状态: %3d”
E301015 “Specify user's individual nozzle No.”
“%s | 设置用户个别吸嘴号。”
[Cause]
When measuring the width of a nozzle's outer shape by laser, the output does not coincide with that of
a standard nozzle. Therefore, the nozzle number can not be set automatically. As a temporary nozzle
No., the smallest nozzle number (530) of option nozzles is set for the nozzle.
[Treatment]
If the nozzle is a standard nozzle, please measure it again. If the same result comes out, something
might be wrong with the nozzle shape. Please check the nozzle. If the nozzle is an option nozzle, the
nozzle number set is just a temporary number and might be wrong. Please set a nozzle number for the
nozzle again. If you measure the nozzle again after set a nozzle number for the nozzle, the temporary
nozzle number will be set again.
E301016 “An error occurred while taking nozzles off”
“因卸下吸嘴,发生错误。”
[Cause]
This message occurs when the machine determines that the nozzle is still on the head even despite the
nozzle removal took place.
[Treatment]
If the nozzle is not on the head, the laser might be too dirty to work properly. Please clean the laser.
Also, please check and see if the slide plate can slide properly or the sensor works properly with
Manual control. If the slide plate or the sensor does not work well, something might be broken. Please
take a note of the error No. and contact our technical service dept. for information.
E301017 “Selected device can not move to this position. | Please reselect other device on HOD”
“被选设备不能移到目标位置。|请重新选择其它设备。”
[Cause]
You cannot go into the teaching mode since you can not move to the specified position with the
device selected by HOD.
[Treatment]
Please reselect a device available.
E301018 “Selected device is not installed. | Please reselect other device on HOD”
“被选设备尚未安装。|请重新选择其它设备。”
[Cause]
Since the device selected by HOD has not been installed (the installation of the device is not set in the
option of MS parameter), you can go into the teaching mode.
[Treatment]
Please reselected a device available.
E301019 “Return to home has not yet been completed”
“尚未完成原点返回。”
[Cause]
The axis has not yet returned to home.
[Treatment]
Please perform the Return to home with ORIGIN switch.
E301020 “MTC power off”
“没有打开 MTC 电源。”
[Cause]
Failed to draw MTC shuttle out when teaching MTC shuttle pick position to the machine since MTS
was not ON.
[Treatment]
Please turn on the power supply of MTC.
E301021 “MTC offline”
“MTC 处于脱机状态。”
[Cause]
Failed to draw the MTC shuttle out when teaching MTC shuttle pick position to the machine since
MTC was not online.
[Treatment]
Please make MTC online.
E301022 “File I/O Error|Error code:%02d|File name:%s”
“文件 I/O 错误|错误代码:%02d|文件名:%s”
E301023”There is no installed head”
“不存在可用 Head。”
[Cause]
There is no head available.
[Treatment]
Please set any necessary heads to “use” in the Use unit in Machine Setup.
E301024 “Selected device is disable. | Please reselect other device on HOD”
“被选设备是不能使用设备。|请重新选择别的设备。”
[Cause]
Since the device selected by HOD is non-use device (it is set to “not use” in the Use unit in Machine
Setup), you can not go into the teaching mode.
[Treatment]
Please select a device available.
E301025 “MTC is disable”
“MTC 不能使用。”
[Cause]
MTC can not be controlled since it is non-use device (it is set to “not use” in the Use unit in Machine
Setup)
[Treatment]
Please set the MTC to “use” in the Use unit in Machine Setup.
E301026 “Servo is in the free state”
“伺服处于未使用状态。”
[Cause]
The axis could not move since the servo is not locked.
[Treatment]
Please lock the servo with S-FREE switch.
W301027 “Teached data is invaled”
“示教数据无效。”
[Cause]
When an error caused by 'out of the measurement range' occurred while learning the Z axis coordinate
by HMS (when “---” is shown for Z in the teaching dialog), you can not learn the coordinate even if
you hit the enter key on HOD. The coordinate also can not be learned when other error occur while
teaching.
[Treatment]
When you learn the coordinate of Z axis by HMS, please make sure that the coordinate is within the
measurement range.
E301028 “Length of the nozzle is too short. | Please check the nozzle”
“吸嘴长度过短。|请检查吸嘴。”
[Cause]