JUKI贴片机错误代码集合.pdf - 第99页
specification in the production program.) ” “ 在设置中, 左站台被设置成不使用状 态。 | 不能进行生产 ( 在生产程序内已经指 定左 Head) 。 ” E500248 “ It is a setup and a right station is unused.|Pr oduction cannot be executed.(There is Right head specificatio…
There is a Component or Pick data that is from a feeder which is not set 'to use' in the Setup.
[Treatment]
Please go to the Production Program Editor and see the Component and Pick data.
E500230 “An error occurred in the checking prior to the production.|Production can not be executed.”
“开始生产之前的检查发生错误,|不能进行生产。”
E500231 “The warnings are over 100 issues in the checking prior to the production.|Production can not be
executed.”
“开始生产之前的检查,发现 100 件以上的警告,|不能进行生产。”
E500240 “The head of the same number which can be used is not at a right and left station.|(There is both
head specification in the production program.)|Production cannot be executed.”
“与可用 Head 同样编号的 Head,在左右站台上都不存在,|(在生产程序内已经指定两边
Head)|不能进行生产。”
E500241 “The head which can be used is not at a left station.|(There is left head specification in the
production program.)|Production cannot be executed.”
“在左边站台上,不存在可以使用的 Head,|(在生产程序内已经指定左边 Head)|不能进行生
产。”
E500242 “The head which can be used is not at a Right station.|(There is Right head specification in the
production program.)|Production cannot be executed.”
“在右边站台上,不存在能使用的 Head,|(在生产程序内已经指定右边 Head)|不能进行生
产。”
E500243 “Right and left OCC is unused.|(There is both head specification in the production
program.)|Production cannot be executed.”
“没有使用左右 OCC|(在生产程序内已经指定两边 Head),|不能进行生产。”
E500244 “Left OCC is unused.|(There is left head specification in the production program.)|Production cannot
be executed.”
没有使用左 OCC|(在生产程序内已经指定左边 Head),|不能进行生产。”
E500245 “Right OCC is unused.|(There is Right head specification in the production program.)|Production
cannot be executed.”
“没有使用右 OCC|(在生产程序内已经指定右边 Head),|不能进行生产。”
E500246 “The station which it is a setup and is unused exists.|Production cannot be executed.(There is both
head specification in the production program.)”
“在设置中,站台被设置成不使用状态。|不能进行生产(在生产程序内已经指定两边 Head)。
E500247 “It is a setup and a left station is unused.|Production cannot be executed.(There is left head
specification in the production program.)”
“在设置中,左站台被设置成不使用状态。|不能进行生产(在生产程序内已经指定左 Head)。”
E500248 “It is a setup and a right station is unused.|Production cannot be executed.(There is Right head
specification in the production program.)”
“在设置中,右站台被设置成不使用状态。|不能进行生产(在生产程序内已经指定右 Head)。”
E500250 “The head which can be used does not exist.|Production cannot be executed.”
“不存在可用 Head。|不能进行生产。”
E500251 “Because the OCC is unused, the mark recognition cannot be executed.|Production cannot be
executed.”
“因没使用 OCC,不能识别标记。|不能进行生产。”
E500252 “The station which can be used does not exist.(It is the setup data and both stations are
unused.)|Production cannot be executed.”
“不存在可用站台。(在设置中,没有使用两边站台) |不能进行生产。”
E500253 “The use nozzle is not in ATC.|Production cannot be executed.”
“在 ATC 上不存在要使用的吸嘴。|不能进行生产。”
E500260 “There is no adjustment in setting the use unit.|Production cannot be executed.”
“使用单元的设置不匹配。|不能进行生产。”
E500261 “The adsorption position is only at a left station.|(A left station (head or OCC or station) is
unused.)|Production cannot be executed.”
“只有左边站台上,存在吸取位置|(没有使用左边站台的(Head,OCC, 站台)),|不能进行
生产。”
E500262 “The adsorption position is only at a right station.|(A right station (head or OCC or station) is
unused.)|Production cannot be executed.”
“只有右边站台上,存在吸取位置|(没有使用右边站台的(Head,OCC, 站台)),|不能进行
生产。”
E500263 “The use nozzle is only at a left station.|(A left station (head or OCC or station) is
unused.)|Production cannot be executed.”
“只有左边站台,存在可用吸嘴|(没有使用左边站台(Head,OCC,站 台 )),|不能进行生产。”
E500264 “The use nozzle is only at a right station.|(A right station (head or OCC or station) is
unused.)|Production cannot be executed.”
“只有右边站台,存在可用吸嘴|(没有使用右边站台(Head,OCC, 站台)),|不能进行生产。”
E500265 “The adsorption position is only at a left station.|The use nozzle is not at a left station.|Production
cannot be executed.”
“只有左边站台,存在吸取位置,|左边站台上没有可用吸嘴,|不能进行生产。”
E500266 “The adsorption position is only at a left station.|The use nozzle is not at a right station.|Production
cannot be executed.”
“只有右边站台,存在吸取位置,|右边站台上没有可用吸嘴,|不能进行生产。”
E500270 “Smaller layer than the layer of the entrance side station exists in the installing data of the exit side
station.”
“出口侧站台的贴片数据上,存在比入口侧站台小的阶层。”
E500271 “It is the data which the exit side station installs earlier than the entrance side station.|Production
cannot be executed.”
“出口侧站台存在比入口侧站台先贴片的数据,|不能进行生产。”
E500272 “There is no adjustment in setting the adsorption position and the use unit.|Production cannot be
executed.”
“吸取位置或使用单元的设置不一致,|不能进行生产。”
E500300 “Origin retrieval has not yet been completed”
“尚未完成返回原点。”
[Cause]
You tried to resume the production without completing the Origin retrieval after an unexpected stop
such as Emergency stop.
[Treatment]
Please perform the Origin retrieval by pressing the ORIGIN button on the operation panel.
E500301 “Servo is turned OFF”
“伺服被关闭。”
[Cause]
The production can not be executed since the Servo is free.
[Treatment]
Please perform the Origin retrieval by pressing the ORIGIN button on the operation panel.
E500302 “Air was down”
“气压被下降。”
[Cause]
The air pressure is getting down.
[Treatment]
Please adjust the air pressure to its original level.
E500303 “Detected %s feeder float”