"在%dth 程序中的图像数据不完全。"
E6427 “Specified number supplied in %dth program exceeds resource. “
"在 %dth程序供给指定数量超过资源数。"
E6428 “Assigned placement data in %dth program exist in multiple stations. “
"在%dth 程序中的指定贴片数据存在于多个位置。"
E6429 “Assigned pick data in %dth program exist in multiple stations. “
"在%dth 程序中的指定挑选数据存在于多个位置。"
E6440 The number of placemently resident nozzles exceeds the resource.
"固定吸嘴数量超过资源量。"
[Cause]
The number of the placement nozzles has exceeded the available number of resources.
[Deal]
Increase the number of nozzles specified in the MSL setup resource.
E6441 “Number of permanent feeders exceeds resource. “
"固定进料器数量超过资源量。"
E6442 %s over resource.
[Cause]
The number of feeders has exceeded the available number of resources.
[Deal]
Increase the number of feeders specified in the MSL setup resource.
E6450 “Permanent data cannot be set. “
"永久数据不能被设置。"
E6451 “Protected data cannot be set. “
"保护数据不能被设置。"
E6452 “
Production control data allocation failed. “
"产品控制数据分配失败。"
E6453 “Production condition data allocation failed. “
"产品情况数据分配失败。"
E6454 “Global fiducial data allocation failed. “
"球型基准数据分配失败。"
E6455 “Permanently resident nozzle allocation failed. “
"永久的常驻的吸嘴分配失败。"
E6456 “Permanently resident feeder allocation failed. “
"永久的常驻的进料器分配失败。"
E6457 “Already assigned pick data allocation failed. “
"已经指定的挑选数据分配失败。"
E6458 “A station to which pick data have already been assigned is excluded as an object of partition. “
"已经被指定的选择数据位置作为区分目标被排除."
E6459 “Already assigned placement data allocation failed. “
"已经指定的贴片数据分配失败。"
E6460 The head corresponding to the already assigned placement data cannot be used.
"已分配给位置的相应的头没有使用。"
[Cause]
Indicates that the station specified for the feeder in mounting and absorption data is different from the
allocated station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6461 “The already assigned placement data MTC cannot be used. “
"不能使用已指定贴片数据 MTC。"
E6462 Some pick data are designated in non-distrubutable station.
"不能设置已指定贴片数据吸嘴。"
[Cause]
Indicates that the data for the absorbing point specification has been already used for the occupation
data.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6463 Some placement data are designated in non-distributable station.
"已指定的贴片数据贴片层相互矛盾。"
[Cause]
Indicates that the data for mounting specification is allocated for more than one station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6464 Already assigned placement data chip standing cannot be detected.
"不能检测到已指定贴片数据的固定芯片站立。"
[Cause]
Indicates that the number of the mounting positions has exceeded the maximum value, i.e., checking
the occupation data was failed.
[Deal]
Decrease the number of mounting positions.
E6465 Already assigned placement data chip standing cannot be detected.
[Cause]
Indicates that inconsistency was found in the layer specification.
[Deal]
Reset the layer allocation for optimization.
E6500 “Data cannot be assigned to machine station. “
"数据不能被指定到机器位置。"
E6550 Failed to distribute data.
"没有%d 数据能被指定到机器位置。"
[Cause]
An invalid data was found during data allocation for the mounting or absorption list. (See the sub-list
for details.)
(Detailed messages corresponding to each station.)-Unavailable for specification since it is an
applicator. Type 770 or 775 station.
-Unavailable for dividing destinations. Station with the balance option check is disabled or 0 balance.
-MTC is disabled. Station unavailable for using MTC.
-MTS is disabled. Station unavailable for using MTS.
-Chip standup-detection is disabled. Station unavailable for chip-standup inspection.
-Coplanarity inspection is disabled. Station unavailable for coplanarity inspection.
-The verification is disabled. Station unavailable for the verification.-IC mark part is disabled. Station
unavailable for IC mark.
-Tray-holder is disabled. Type 770 or 775station.
-Nozzle 5 is disabled. Type 770 or 775 station.
-44 and 56 mm feeders are disabled. Type 770 or 775 station.
-The value specified for the outside dimension deviates from the range and not acceptable. Outside
dimension applied to the centering is out of the range.
-The value specified for the part height deviates from the range and not acceptable. Height applied to
the centering is out of the range.-Every head is disabled. Station with all heads disabled.
-General-purpose head is disabled. Station unavailable for general-purpose head.