W650313 “ Idle PWB Conveying Erro r: A PWB i s detected on the center stati on on the Exi t side. Please remove it ” “ 传送基板 ( 通过 ) 错误 : | 出口侧中心缓冲区发现基板。 ” [Cause] In the KE2030 Idl e PWB Conveying process, unexp ected PWB…
Ref. pin sensor is broken. It could be that the wiring came off the connector, that a contact pin in the
connector part is broken, that wiring got cut off, or that sensor itself is broken. Please examine the
wiring and the connector. If any of them are broken, you need to replace them with new ones.
3) When the Ref. pin sensor in the 'Status' frame does get ON/OFF, there is a possibility that the
signal line of the Ref. pin sensor is broken. It could be that the wiring came off the connector part,
that a contact pin in the connector part is broken, or that signal line got cut off. Please examine the
wiring and the connector. There also is another possibility that the screw that holds the encoder and
the encoder axis together is loose. Please make sure that the screw is tightened up enough.
4) If the treatments mentioned above do not work, a PCB is broken or the wiring between the PCBs is
bad.
E650297 “Clamp Error :| Backup plate stopper of the center buffer | on the Exit side lock up illegally.”
“基板固定错误 :|出口侧中心缓冲区,支撑台制动器固定错误。”
E650298 “Clamp Error :| Backup plate stopper of the center buffer | on the Exit side release illegally.”
“基板固定错误 :|出口侧中心缓冲区,支撑台制动器释放错误。”
W650309 “Idle PWB Conveying Error : PWB is detected on the conveying route. Please remove it”
“传送基板(通过)错误 :|传送轨道上发现基板。”
[Cause]
In the Idle PWB Conveying process, several buffers on the conveying route detected unexpected
PWBs on the conveying route.
[Treatment]
Please remove the PWBs on the conveyor.
W650311 “Idle PWB Conveying Error : A PWB is detected on the center station. Please remove it”
“传送基板(通过)错误 :|中心缓冲区发现基板。”
[Cause]
In the Idle PWB Conveying process, unexpected PWBs were detected on the center station on the
conveyor.
[Treatment]
Please remove the PWBs on the center station.
W650312 “Idle PWB Conveying Error : A PWB is detected on the center station on the Entrance side. Please
remove it”
“传送基板(通过)错误 :|入口侧中心缓冲区发现基板。”
[Cause]
In the KE2030 Idle PWB Conveying process, unexpected PWBs were detected on the center station
on the Entrance side on the conveyor.
[Treatment]
Please remove the PWBs on the center station on the Entrance side.
W650313 “Idle PWB Conveying Error: A PWB is detected on the center station on the Exit side. Please
remove it”
“传送基板(通过)错误 :|出口侧中心缓冲区发现基板。”
[Cause]
In the KE2030 Idle PWB Conveying process, unexpected PWBs were detected on the center station
on the Exit side on the conveyor.
[Treatment]
Please remove the PWBs on the center station on the Exit side.
W650314 “Idle PWB Conveying Error : A PWB is detected on the OUT buffer. Please remove it”
“传送基板(通过)错误 :|出口缓冲区发现基板。”
[Cause]
In the Idle PWB Conveying process, unexpected PWBs were detected on the OUT buffer conveyor.
[Treatment]
Please remove the PWBs on the OUT buffer on the conveyor.
W650319 “Idle PWB Conveying Error : In operation of Idle PWB conveying”
“传送基板(通过)错误 :|正在运行传送基板(通过)。”
[Cause]
A new request of PWB conveying was issued before a previous request of PWB conveying got
complete (Program error).
[Treatment]
Please see the error message, and remove all the PWBs on the conveyor. Then try the request again.
E650321 “Idle PWB Conveying Error : Illegal input buffer motor movement. The process is forcibly
terminated. Please remove on the conveying route”
“传送基板(通过)错误 :|入口缓冲区马达运转异常。”
[Cause]
Since IN sensor detected a PWB coming in, the belt of the INPUT buffer got started to drive and the
PWB was taken in to the INPUT buffer. However, the IN sensor did not get OFF after a certain
amount of time has passed. Usually, this error occurs when a PWB can not go through the INPUT
buffer for some reason.
[Treatment]
1 If the PWB was on the position where it is detected by IN sensor when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The PWB can not go through smoothly since the conveyor is not connecting well to the machine in
the upper part of the line. Please re-adjust the connection.
2) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
3) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by IN sensor when the error
occurred.
If the IN sensor does not get OFF when a PWB is properly being conveyed, there is a possibility that
the sensor is detecting something else. Please select [Manual Control] from the menu bar, and then
select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of IN sensor
in the 'Status' frame.
1) If there is anything that IN sensor reacts to underneath the IN sensor, please remove it from under
the sensor or change the position of the sensor. I
2) If the treatment1 does not work, please adjust the sensitivity of the sensor, using the volume
control knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the IN sensor is broken. It could be that
the wiring came off the connector part, that a contact pin in the connector part is broken, that wiring
got cut off, or that the sensor itself is broken. Please examine the wiring and the connector. If any of
them are broken, you need to replace them with new ones.
4) If the treatment3 does not work, a PCB is broken or the wiring between the PCB is bad.
E650322 “Idle PWB Conveying Error : PWB conveying error of Input buffer. The process is forcibly
terminated. Please remove on the conveying route”
“传送基板(通过)错误 :|入口传感器/等待传感器同时打开错误。”
[Cause]
The belt of INPUT buffer got started to drive and a PWB was taken in to the INPUT buffer but the IN
sensor did not get OFF even if the WAIT sensor detected the PWB. The PWB is taken in to the
INPUT buffer and, if the WAIT sensor detects the PWB< the PWB conveying stops sand the PWB
gets in the a waiting mode, At this point, the IN sensor should not detect anything.
[Treatment]
1 The PWB had been detected by WAIT and IN sensors when the error occurred,
1) The installation positions of IN and WAIT sensors are not correct. Please adjust the positions so
that the sensors do not detect anything at the same time.
2) The PWB you are trying to convey does not match the specifications of your machine. A machine
with M size specification can not deal with PWB that is over 330mm, a machine with L size
specification can not deal with PWB that is over 410mm, and a machine with E size specification can
not deal with PWB that is over 510mm.
2 The PWB was staying on the position where IN sensor detected the PWB when the error
occurred (the error occurred before the PWB got to the WAIT sensor).
There is a possibility that the WAIT sensor detected something while the PWB was conveyed to the
Input buffer. Please select [Manual Control] from the menu bar, and then select [Control(C)]
[Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of WAIT sensor in the 'Status'