JUKI贴片机错误代码集合.pdf - 第72页

E301077 “ IP address 0.0.0.0 is invalid .” “ 0.0.0.0 是不正确的 IP 地址。 “ E301078 “ The IP address contains blanks .” “ IP 地址上 有空格。 “ Q302000 “ Reset I/O? ” “ 是否进行各 I/O 的安全方向设定? ” [Cause] You are asked if to set each I /O in t…

100%1 / 464
E301062 There is no head that can move to specified position.”
不存在可以移到指定位置的吸嘴。
W301063 Selected MTC/MTS is not connected.”
已被选用的 MTC/MTS 处于脱机状态。
E301064 MTS is in the supply state.”
MTS 处于补充状态。
E301065 %s ||Specified nozzle data has not been registered.|Please register nozzle data.”
%s ||吸嘴信息没有注册。|请注册吸嘴信息。
E301066 The nozzle no. is invalid.”
无效的吸嘴号。
E301067 A drive can not be access.|Please check the FD
不能访问 A 驱动器。|请确认一下软盘。
E301068 Because the right head is disable, it can not be measured.”
因为 Head 处于不使用状态,所以不能进行测量。
E301069 Input value exceeds predetermined data range.”
输入数据超过范围。
E301070 It can not be set the small nozzle on a large ATC.”
大型 ATC 上不能安装小型吸嘴。
E301071 The SemiAuto Trash box is not at the abandonment position.|Please set the SemiAuto Trash box at
the abandonment position.”
半自动废弃盒不在废弃位置。|请把半自动废弃盒设置在废弃位置。
E301072 The production program has not read.”
不能读取生产程序。
E301073 An error occurred while BOC alignment.”
BOC 校准发生错误。
E301074 An error occurred while BOC Mark Correct.”
BOC 标记校正发生错误。
W301075 Because the nozzle data[ %s ] is initial data, it can not be delete.”
因为被选吸嘴的信息[ %s ]是初始数据,不能删除。
W301076 Input value exceeds the simultaneous BOC mark recognition limit.|Please check out the Y value.”
输入值超过了同时识别 BOC 标记的范围。|请检查一下 Y 坐标值。
E301077 IP address 0.0.0.0 is invalid.”
0.0.0.0 是不正确的 IP 地址。
E301078 The IP address contains blanks.”
IP 地址上有空格。
Q302000 Reset I/O?
是否进行各 I/O 的安全方向设定?
[Cause]
You are asked if to set each I/O in the safety direction.
[Treatment]
YES button will sets I/O in the safety direction.
NO button will discontinue to exit the Manual control.
Q302001Exit machine setup. | Set value is saved?
退出机器设置。|是否保存设置?
[Cause]
You are asked if to save the parameter that was set in Machine Setup.
[Treatment]
YES button will save the set value.
NO button will not save the set value.
Cancel button will cancel your inquiry.
Q302002 Error has occurred during automatic measurement of nozzle. | Do you interrupt automatic
measurement?
吸嘴的自动测量发生错误。|是否停止自动测量?
[Cause]
An error occurred during the auto. nozzle measurement of ATC nozzle allocation. You are asked if to
abort the following ATC auto. measurement.
[Treatment]
YES button will abort the auto. measurement.
NO button will continue the auto. measurement.
Q302003 Return to home has not yet been completed. | Return to home?
未完成原点返回。|是否进行原点返回?
[Cause]
The axis has not returned to home yet. You are asked if to perform Home returning.
[Treatment]
YES button will perform the Home returning, and continue the process.
NO button will not perform the Home returning, but continue the process.
Q302004 Error has occurred during nozzle installation. | Move to parking position?
安装吸嘴发生错误。|是否移到待命位置?
[Cause]
A nozzle installation error of ATC nozzle allocation occurred. You are asked if to move the head to
the nozzle removal position.
[Treatment]
YES button will move the head to the nozzle removal position, and continue the process.
NO button will not move the head to the nozzle removal position, but continue the process.
Q302005 Extend shuttle?
是否取出滑梭?
[Cause]
You are asked if to draw a shuttle out of MTC when teaching the MTC shuttle pick position to the
machine.
[Treatment]
YES button will draw the shuttle from MTC, and get in the teaching mode.
NO button will no draw the shuttle from MTC, but get in the teaching mode.
Q302006 Do you interrupt automatic measurement?
是否停止自动测量?
[Cause]
STOP switch was pressed while nozzle were automatically assigned. You are asked if to abort the
auto. measurement.
[Treatment]
YES button will abort the auto. measurement.
NO button will continue the auto. measurement.
Q302007 A nozzle is fixed to %s. | Do you want to auto-return the nozzle?
吸嘴被装配在%s |是否自动放回吸嘴
[Cause]
With a nozzle on the head, the head in the Use unit was changed to not use from use You are
asked if to return the nozzle to ATC before enabling the change.
[Treatment]
YES button will return the nozzle installed on the head.
NO button will enable the change with the nozzle on the head. When you choose NO, you need
to cancel the nozzle allocation in the 'ATC nozzle allocation'.
Q302008 Extend MTS mark?
是否获取 MTS 标记?
[Cause]