JUKI贴片机错误代码集合.pdf - 第25页
[Cause] You could not move the Yc table. Y 方向中心支撑台不能 移动。 [Treatment] Please check and see if the Yc ta ble can move properly with Man ual control . 请以“手动控制”检查 Yc 支撑台能不能正常活动。 E240003 “ The axis margin out of range. It is …
E192005 “A system error occurred.|Failed in the opening of the mail of the production control.|Detail
code=0x%08X”
“发生系统错误。|打开生产管理邮件失败。|详细代码=0x%08X”
E192006 “A system error occurred.|Failed in the opening of the shared memory.|Detail code=0x%08X”
“发生系统错误。|打开共享内存失败。|详细代码=0x%08X”
E192007 “A system error occurred.|Failed in the close of the shared memory.|Detail code=0x%08X”
“发生系统错误。|关闭共享内存失败。|详细代码=0x%08X”
E192008 “A system error occurred.|Failed in the acquisition of the computer name.|Detail code=%d”
“发生系统错误。|取得计算器名称失败。|详细代码=%d”
W192100 “Retry List message file (%s) cannot be opened.”
“不能打开重试列表信息文件(%s)。”
第二章 组件测量
[组件测量、跟踪、Verify 检查、视觉识别、LSC 识别、照明确定、共面性检查、识别送料器台架、标记数据库]
E240000 “The axis cannot be moved”
“轴不能移动。”
[Cause]
The axis could not move for some reason.
轴不能移动。
[Treatment]
Please check and see if the axis can move properly with Manual control.
请以“手动控制”检查轴能不能正常活动。
E240001 “The axis cannot be moved to escape point”
“不能移到轴等待位置。”
[Cause]
You could not move the axis to the Escape point.
轴不能移动到等待位置。
[Treatment]
Please check and see if the axis can move properly with Manual control.
请以“手动控制”检查轴能不能正常活动。
E240002 “Yc table cannot be moved”
“Yc 支撑台不能移动。”
[Cause]
You could not move the Yc table.
Y 方向中心支撑台不能移动。
[Treatment]
Please check and see if the Yc table can move properly with Manual control.
请以“手动控制”检查 Yc 支撑台能不能正常活动。
E240003 “The axis margin out of range. It is not possible to operation”
“因超过范围,轴不能移动。”
[Cause]
You could not move the axis since it went out of its movable range.
因为轴移动位置超出活动范围,所以不能移到位。
[Treatment]
Please check and see if its coordinates are correct.
请检查坐标。
E240004 “The interrupt which was not able to operate was detected. | The trace is ended”
“发现不能动作的阻碍。|停止跟踪。”
[Cause]
The process was forcibly aborted since an interruption, such as axis alarm and Emergency STOP, that
stops every kind of actions was detected.
[Treatment]
Please check and see if any alarms occurred, and deal with causes of the alarm.
E240005 “The area sensor was detected. | Please remove the sensor reaction factor”
“因范围传感器发现错误而暂停。|请排除故障。”
[Cause]
Tracing got paused since the area sensor detected something.
[Treatment]
Please removed a factor detected by the sensor, and resume tracing.
E240006 “The feeder float sensor was detected. | Please remove the sensor reaction factor”
“发现传送带浮动。|请矫正传送带。”
[Cause]
Tracing got paused since the feeder float sensor detected something.
[Treatment]
Please removed a factor detected by the sensor, and resume tracing.
E240007 “Input is mistake”
“输入错误。”
[Cause]
Something was wrong with the characters when you hit Enter key to define characters.
[Treatment]
Please re-enter characters
E240008 “There is no data previous”
“前面没有数据。”
[Cause]
This error occurs when there is no data ahead to trace.
[Treatment]
Check only
E240009 “There is no data next”
“后面没有数据。”
[Cause]
This error occurs when there is no data behind to trace.
[Treatment]
Check only
E240010 “Specified device cannot be used”
“指定设备不能使用。”
[Cause]
The specified device is set to “not use” in the Use unit in Setup.
[Treatment]
If the device is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot
be executed.
E240011 “The station is different”
“站点不同。”
[Cause]
This error occurs when the side the HOD device is on is wrong when teaching.
[Treatment]
Please check and see which device (left or right) to use.
E240012 “Specified position not move”
“不能移到指定坐标。”
[Cause]
You could not move the axis to the specified position since the axis went out of its movable range.
[Treatment]
Please check and see if the coordinates are correct.
E240013 “The origin point return is non-completion”尚未结束返回原点。”