JUKI贴片机错误代码集合.pdf - 第393页

“ 因 VAC 电磁阀故障,发生动作迟钝现象 。 | 需要更换 VAC 电磁阀。 ” W901405 “ Stuff in the air filter o n the nozzle axis side.|Ai r filters ne ed to be changed .” “ 吸嘴轴侧的空气过滤器被塞满。 | 需要 更换空气过滤器。 ” W901406 “ Latency of movement occurred due to t …

100%1 / 464
VCS识别校准块D时发生错误。|代码: %ld|(选择[确定],把校准D归还到校准块上)
E901202 Error has occurred during acknowledgment of mark.|Code: %ld
识别标记时发生错误。|代码: %ld
E901203 Error has occurred when measuring center-to-center distance of marks.|Code: %ld
测量标记中心间距时发生错误。|代码: %ld
E901204 Error has occurred during scaling setting.|Code: %ld
设置缩放比例时发生错误。|代码: %ld
E901301 Error has occurred on axis.|Code: %ld
轴发生错误。|代码: %ld
E901302 Error has occurred on axis of XY.|Code:%ld
XY轴发生错误。|代码:%ld
E901303 Error has occurred on axis of Z. (%s)|Code: %ld
Z轴发生错误。(%s)|代码: %ld
E901304 Error has occurred on axis of Theta. (%s)|Code: %ld
θ轴发生错误。(%s)|代码: %ld
E901305 The initialization error of transportation occurred. | Return to home is interrupted. Error code:%ld
搬运的初始化发生错误。|停止返回原点。错误代码:%ld
E901306 The PWB was detected in the transportation road.”
传送轨道上有基板。
W901401 1.Vacuum generating power of ejector is beyond regular level.|Ejectors need to be changed.|2.Air is
leaking from the air pipe path |Air paths need to be inspected.”
1.真空发生器的真空吸引力为规格之外。|需要更换排出器。|2.发生空气管道漏气|需要
检查空气管道。
W901402 1.Vacuum generating power of ejector is low.|Ejectors need to be changed.|2.Air is leaking from
the air pipe path |Air paths need to be inspected.”
1.真空发生器的真空吸引力偏低。|需要更换排出器。|2.发生空气管道漏气。|需要检查空
气管道。
W901403 Stuff in the air filter on the nozzle axis side.|Air filters need to be changed.”
吸嘴轴侧的空气过滤器被塞满。|需要更换空气过滤器。
W901404 Latency of movement occurred due to the VAC electromagnetic valve trouble.|VAC
electromagnetic valves need to be changed.”
VAC电磁阀故障,发生动作迟钝现象|需要更换VAC电磁阀。
W901405 Stuff in the air filter on the nozzle axis side.|Air filters need to be changed.”
吸嘴轴侧的空气过滤器被塞满。|需要更换空气过滤器。
W901406 Latency of movement occurred due to the VAC electromagnetic valve trouble.|VAC
electromagnetic valves need to be changed.”
VAC电磁阀故障,发生动作迟钝现象|需要更换VAC电磁阀。
W901407 Stuff in the air filter on the nozzle axis side.|Air filters need to be changed.”
吸嘴轴侧的空气过滤器被塞满。|需要更换空气过滤器。
W901408 Stuff in the nozzle axis part of ejector.|Ejectors need to be changed.”
真空发生器的吸嘴轴部被塞满。|需要更换发生器。
W901409 Latency of movement occurred due to the Blow electromagnetic valve trouble.|Blow
electromagnetic valves need to be changed.”
因吹气电磁阀的故障,发生动作迟钝现象。|需要更换吹气电磁阀。
E901501 Error has occurred during acknowledgment of jig component by L3.|Status:%02x Error
code:%02x
发生L3识别故障。|状态:%02x 出错代码:%02x
E901502 Error has occurred during acknowledgment of jig component by L3.”
发生L3识别故障。
E901601 The combination starting from ATC No. %s exceeded the allowable range.”
ATC %s号开始同时交换吸嘴时,偏差超过允许范围。
E901701 The starting point position of LSC is outside the range. | The position of a starting point sensor
needs to be readjusted.”
LSC的原点位置超过允许范围。|有必要调整原点传感器的位置。
Q902001 Reset I/O ?
是否设置I/O安全方向?
Q902002 Exit Ms parameters.|Save changes ?
退出MS参数设置。|是否保存设置?
Q902011 Return to home has not yet been completed.|Return to home ?
尚未运行返回原点。|是否进行返回原点?
Q902012 %s descends. Is there feeder etc. below the head ?
%s下降。Head底下是否有送料器等?
Q902021 Current set value will be lost.|Do you interrupt file read ?
Current set value will be lost.|Do you interrupt file read ?
Q902022 EEPROM will be erased.|Do you interrupt erase EEPROM ?
EEPROM will be erased.|Do you interrupt erase EEPROM ?
Q902031 Do you measured center of component ?
是否运行识别组件中心?
Q902032 Do you return jig ?
是否归还模具?
Q902033 Return CAL piece to CAL piece holder ?
是否把校准块(CAL piece)归还到校准块固定器?
Q902041 Current version is %s|Would you like to upgrade ?
当前VCS版本是%s|是否要升级?
Q902042 Current I/O version is %s|Would you like to upgrade ?
当前I/O版本是%s|是否要升级?
Q902043 Current B/F version is %s|Would you like to upgrade ?
当前B/F版本是%s|是否要升级?
Q902044 The program data on I/O CPU is deleted.|Would you like to delete the data ?
删除I/O CPU程序数据。|是否继续?
Q902045 The program data on B/F CPU is deleted.|Would you like to delete the data ?
删除B/F CPU程序数据。|是否继续?
Q902046 Current MCM/MCMR version is %s|Would you like to upgrade ?
当前MCM/MCMR版本是%s|是否要升级?
Q902047 Formats the vision system flash memory.| Are you sure you want to format the memory?
将格式化图像处理装置的闪存卡。|否继续?
Q902050 Do you interrupt measurement ?
是否停止测量?
I903001 Conveyor reference plane has been changed.|An attachment position of units is changed.”
搬运设计被改变。|变更单元的装配位置。
I903002 Component height has been changed.|Design position of Z axis is initialized.”
组件高度被更新。|初始化Z轴坐标系的设计值。