Copyright © ViT rox All Rights Reserved . 1 14 Joint Inspection Algorithm

Copyright © ViTrox All Rights Reserved.
113
4. Presence Thres (um)
● Need to enable 3D mode.
● Inspected lead height higher than Presence Thres (um) to pass the
inspection.
5. Coplanarity
● Need to enable 3D Mode.
● Can adjust the location for the coplanarity ROI based on the predefined list.
● 2 modes: Corner & Cross
CoplanThres
Pass Fail
6. Coplan Thres (um)
● Fail when the difference between the 2 opposite ROI larger than the coplan
threshold.
Corner Cross
S-type Algorithm - Body Mode (Classic)

Copyright © ViTrox All Rights Reserved.
114
Joint Inspection Algorithm

Copyright © ViTrox All Rights Reserved.
S-Type Algorithm - Joint Inspection
115
1. Lead Inspection
● Consists of 2 modes.
Mode Description
Relative Software will calculate the average height for each lead and
used it as the reference height for lifted lead inspection.
Absolute Lead Height (um) that we keyin will be used as the reference
height for lifted lead inspection.
2. Lead Height
● To pre set the height for the lead.
● Need to use this value during lifted lead inspection.