Smart Gui - Algorithm Training Material_rev1.pdf - 第69页
Copyright © ViT rox All Rights Reserved . B-type Algorithm - Joint (T erminal Reference) 69 1. Joint Image Plane ● Solder Inspection consists of 3 mode. Which are: 2. Joint Grey Thres ● These are the types of 2D Lighting…

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Joint
68
1. Solder Inspection
● Solder Inspection consists of 3 mode. Which are:
Difference between Terminal & Base
Terminal Reference:
Solder height qualification is based on the height (%) between lead
terminal & PCB surface
Base Reference:
Solder height qualification is based on the height (um) measured from
PCB surface.

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Joint (Terminal Reference)
69
1. Joint Image Plane
● Solder Inspection consists of 3 mode. Which are:
2. Joint Grey Thres
● These are the types of 2D Lighting. Select the one with
having highest contrast among interested inspection region
and the background.
● Usually choose angle 2+3
3. Joint Height Thres
Grey Thres
Measured Grey Thres
PASS
FAIL
Height Thres (um)
Measured Height(um)
PASS
FAIL

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Joint (Terminal Reference)
70
4. Joint Coverage Thres
● To set the percentage to pass the joint inspection.
Pass Criteria for single pixel:
a. Measured Grayscale < Joint Grey Thres
b. Solder Height (%) > Joint Height Thres (%).
The overall pass criteria depends on:
Joint Coverage (%) > Joint Coverage Thres (%)
where,