Smart Gui - Algorithm Training Material_rev1.pdf - 第50页

Copyright © ViT rox All Rights Reserved . B-type Algorithm - Locator (Location) 50 e. 2D Locator ● T ick this to enable 2D to locate component. f. Location mode. ● Several locate mode that used to locate the component. g…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Locator (Location)
49
a. Advanced Offset
Tick this to enable advanced offset.
To enable the two direction (+ve or -ve) offset threshold
setting
b. Vertical offset & Horizontal offset
To set the offset threshold setting.
c. Skew Thres
10 = 1 degree
d. Skew 3D
To enable 3D to locate skew.
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Locator (Location)
50
e. 2D Locator
Tick this to enable 2D to locate component.
f. Location mode.
Several locate mode that used to locate the component.
g. Image Operator
Select this to process 2 image plane to 1 Image plane.
There are 4 mode as below.
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Locator (Location)
51
h. Binarize Image
Tick this to enable binarize image.
i. Binarize Limit
Grey scale below Binarize Limit turn 255.
Grey scale above Binarize Limit turn 0.
j. Edge (%)
k. Ruler width Multiplier
To adjust the size for the ruler
l. Ruler Smoothing
To filter out the noises at the edge
Enable this when the edges are not clear.