Smart Gui - Algorithm Training Material_rev1.pdf - 第50页
Copyright © ViT rox All Rights Reserved . B-type Algorithm - Locator (Location) 50 e. 2D Locator ● T ick this to enable 2D to locate component. f. Location mode. ● Several locate mode that used to locate the component. g…

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Locator (Location)
49
a. Advanced Offset
● Tick this to enable advanced offset.
● To enable the two direction (+ve or -ve) offset threshold
setting
b. Vertical offset & Horizontal offset
● To set the offset threshold setting.
c. Skew Thres
● 10 = 1 degree
d. Skew 3D
● To enable 3D to locate skew.

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Locator (Location)
50
e. 2D Locator
● Tick this to enable 2D to locate component.
f. Location mode.
● Several locate mode that used to locate the component.
g. Image Operator
● Select this to process 2 image plane to 1 Image plane.
● There are 4 mode as below.

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Locator (Location)
51
h. Binarize Image
● Tick this to enable binarize image.
i. Binarize Limit
● Grey scale below Binarize Limit turn 255.
● Grey scale above Binarize Limit turn 0.
j. Edge (%)
●
k. Ruler width Multiplier
● To adjust the size for the ruler
l. Ruler Smoothing
● To filter out the noises at the edge
● Enable this when the edges are not clear.