Smart Gui - Algorithm Training Material_rev1.pdf - 第36页

Copyright © ViT rox All Rights Reserved . 1. Solder Profile ● Using 2D (Grayscale) and 3D(Height) ● Include Bumpy solder Inspection as fail criteria. ● Pass Criteria for single pixel: a. Measured Grayscale < Joint Gre…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
35
CR Type Algorithm - Joint (Solder Profile Inspection)
Solder Height Thres (um)
It’s used to set the minimum height requirement for the solder joint.
May vary when component body lifted happened.
Solder Height Thres (um)
Solder Height Thres (um)
(At body lifted condition)
Copyright © ViTrox All Rights Reserved.
1. Solder Profile
Using 2D (Grayscale) and 3D(Height)
Include Bumpy solder Inspection as fail criteria.
Pass Criteria for single pixel:
a. Measured Grayscale < Joint Grey Thres
b. Solder Height (%) > Joint Height Thres (%).
c. OR Relation between 2D and 3D as pass criteria for single pixel
The overall pass criteria depends on:
a. Solder Width (%) > Solder Width Thres (%)
b. Solder Length (%) > Solder Length Thres (%)
c. Both solder Length and Solder Width must pass.
36
CR Type Algorithm - Joint (Solder Profile Inspection)
Width
Length
Solder
Peak
Solder Peak Thres (%)
Tick this to enable the solder peak inspection.
Minimum solder peak height must higher than the
Solder Peak Thres (%)
Solder Peak Thres (um)
Solder Peak Thres (%)
Copyright © ViTrox All Rights Reserved.
1. Enable Side Fillet
Tick to enable side fillet inspection.
By 2D only. (Grayscale)
2. Box Mode
3. Joint Image Plane
Select the one that having best contrast among the Joint Area
and background.
4. Threshold Range
To set the range (Min & Max) of threshold to pass the Side Fillet
algorithm.
For eg, Threshold Range to 70 - 190, the measured greyscale
that fall between 70 to 190 will consider as pass.
37
CR Type Algorithm - Joint (Side Fillets Inspection)
1 Box 2 Boxes 3 Boxes
5. Coverage Range (%)
Coverage range is used to set the range (Min & Max)
of coverage to pass the Side Fillet algorithm.
For eg, when coverage range is set to 80 - 100, the
measured coverage that fall between 80 to 100 will
consider as pass.