Smart Gui - Algorithm Training Material_rev1.pdf - 第149页

Copyright © ViT rox All Rights Reserved . 149 1 2 3 4 5 6 7 End Leads End Leads Central Leads End Lead Thres Threshold Ringer T est V alue Lead Number Defect Defect Threshold Sense: Low Bad ● Lead 7 (End Lead) is not fai…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
Lead Ringer - Example for High Bad Thres Sense
148
1 2 3 4 5 6 7
End LeadsEnd Leads Central Leads
End Lead Thres
Threshold
Ringer
Test Value
Lead
Number
Defect
Defect
Threshold Sense: High Bad
Lead 1 (End Lead) is not failing although its exceed the
Threshold” set. This is because lead 1 using “End Lead
Threshold”.
Lead 4 (Central Lead) is failing because its exceed the
“Threshold” set.
Lead 7 (End Lead) is failing because its exceed the “End
Lead threshold”.
Copyright © ViTrox All Rights Reserved.
149
1 2 3 4 5 6 7
End LeadsEnd Leads Central Leads
End Lead Thres
Threshold
Ringer
Test Value
Lead
Number
Defect
Defect
Threshold Sense: Low Bad
Lead 7 (End Lead) is not failing although its below the
Threshold” set. This is because lead 7 using “End Lead
Threshold”.
Lead 4 (Central Lead) is failing because its below the
“Threshold” set.
Lead 1 (End Lead) is failing because its below the “End
Lead threshold”.
Lead Ringer - Example for Low Bad Thres Sense
Copyright © ViTrox All Rights Reserved.
150
Joint Bridging Inspection