Copyright © ViT rox All Rights Reserved . 164 Component Locator Algorithm

100%1 / 331
Copyright © ViTrox All Rights Reserved.
U-type Body Presence
163
f. Extra Part
Tick to revert the logic of body presence which the logic similar to
presence threshold set as negative value.
If Presence Thres set to +150
If Presence Thres set to -150
Presence Thres = 150
Pass
Fail
Presence Thres =150
Pass
Fail
Copyright © ViTrox All Rights Reserved.
164
Component Locator Algorithm
Copyright © ViTrox All Rights Reserved.
U-type Locator - Edge Locator
165
Edge locator is used to locate the component body
by using the edge of body.
a. Pass Criteria
AND Relation: All applied U-type algo must pass in order to pass.
OR Relation: Any one of the applied U-type algo pass will consider
pass.
b. Horizontal Thres (um)
Fail when the measured Horizontal Offset from datum exceed the
Horizontal Thres
c. Vertical Thres (um)
Fail when the measured Vertical Offset from datum exceed the
Vertical Thres
d. Skew Thres (deg)
Fail when the measured component rotation exceed the skew Thres.
1=1 deg