Copyright © ViT rox All Rights Reserved . 289 6. Polarity Periodically Check ● When turn on enable periodic checking and set to 10, every 10th boards that enable polarity periodic check will perform polarity inspection, …

Copyright © ViTrox All Rights Reserved.
288
1. Page Comment
● To leave your remarks.
2. Number of Boxes
● To set the number of boxes used for polarity checking
● 2 boxes or 4 boxes
3. Polarity Box Size & Polarity Box Offset
● To adjust the sizes & offset for the Side Fillet Boxes
● Can drag the boxes to change the size and offset
4. Used Red Box Offset
● To set the red box as the movable box.
● After enable use red box offset, there is additional X and Y able
to fill in.
● Can drag on the boxes.
5. Lock Boxes
● Lock Boxes are used to disable to follow the locator for all
polarity boxes.
Polarity

Copyright © ViTrox All Rights Reserved.
289
6. Polarity Periodically Check
● When turn on enable periodic checking and set to 10, every 10th
boards that enable polarity periodic check will perform polarity
inspection, otherwise the another 9 boards will skip the
inspection. If the board finished inspection when the periodic
count at 6, for the next board inspection, the periodic count will
start from 7.
● Close SmartG software will reset the periodic count. The
programs that did not enable polarity periodic check will inspect
as usual.
Polarity

Copyright © ViTrox All Rights Reserved.
290
6. Calculation Mode
● Calculation mode contains 11 type of calculations that include 9
type of 2D calculations and 2 type of 3D calculations which are:
a. 2D calculation
○ Mean Green Box - Mean Red Box
○ Std Dev of Green Box - std Dev of Red Box
○ (Mean + Std Dev of Green Box) - (Mean + Std Dev of
Red Box)
○ Edge Find, Dark Outside -> Light Inside
○ Edge Find, Light Outside -> Dark Inside
○ Bar Edge Find
○ Dark Circle
○ Bright Circle
b. 3D calculation
○ [3D] Height of Green Box - Height of Red Box
○ [3D] Range of Green Box - Range of Red Box
Polarity