Component Locator Algorithm
Copyright © ViTrox All Rights Reserved.
CR Type Algorithm - Locator
7
1. Search Area
Adjust the XY Dimension for the green box.
Component will be find within the search area.
2. Extra Search Area
Extra Search Area is used to force a component towards
the center of the field of view. (Units:micron)
The Search area extra specifies are area around a
components search are which cannot be allowed to fall at
the edge of the field of view. This could be used for
components which appear different at the edge of the field
of view, e.g. tall components.
It has a maximum value of 20000. A typical value is 15000.
3. Body Size
Adjust the XY Dimension for the blue box.
Component XY Dimension.
Right click on the component and select “Auto Fill Body” to
auto set the body size.
4. Lead Size
Setup the lead XY measurement value when enable 2D
locator mode.
Lead size X
Lead size X
Body size X
Lead size Y = Body size Y
Copyright © ViTrox All Rights Reserved.
CR Type Algorithm - Locator
8
1. 2D Locator
Only use 3D to locate the component location.
Only use 2D to locate the component location.
Select this to enable 2D + 3D Locator
3D as priority, 2D to support
3. Image Plane
These are the types of 2D Lighting. Select the one
with having highest contrast among interested
inspection region and the background.
2. 3D Locator
Auto select 2D or 3D (Whichever is better)
Only use 3D
Only use 3D, The height range can be preset as
below.
Max Height Reverse means Change the max
height to min height.