Copyright © ViT rox All Rights Reserved . U-type Joint- Diff Joint 180 Mode: Inspect Dot 1. Inspection Box Size & Inspection Box Offset ● Interested region to do the inspection. ● T o adjust the inspection box size &…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
U-type Joint- Diff Joint
179
Mode: Save Image
1. Image Plane
These are the types of 2D Lighting. Select the one with having highest
contrast among interested inspection region and the background.
2. Box Size & Box Offset
Interested region to save the base image.
To adjust the box size & box offset.
3. Search Box Size & Search Box Offset
Region to search the base image.
To adjust the search box size & search box offset.
4. Follow Locator
To enable the inspection boxes follow the locator.
5. Correlation Thres
This is the correlation threshold.
Correlation also means as similarity score.
For e.g. Corr thres set to 750
6. Save Base Image
Click this icon to save the base image info.
CorrThres
(75%)
PassFail
Copyright © ViTrox All Rights Reserved.
U-type Joint- Diff Joint
180
Mode: Inspect Dot
1. Inspection Box Size & Inspection Box Offset
Interested region to do the inspection.
To adjust the inspection box size & inspection box offset
.
2. Bright Thres & Dark Thres
3. Dot Min Size & Big Dot Size
To define the minimum Dot size & Big Dot size
4. Small Dot Number
The number of small dot to fail the component
5. Bright/Dark Dot Fail As:
To define the defects name for each defect detected.
Grey Scale
(Base Image)
Pass
Fail
Dark Thres Bright Thres
Fail
Copyright © ViTrox All Rights Reserved.
U-type Joint- Diff Joint
181
Mode: Inspect Box
1. Box Size X & Box Size Y
To adjust the size for the auto partitioned joint box
2. Bright Percentage Thres & Dark Percentage Thres
Box coverage percentage (Within the partition boxes) for bright defect
& dark defect.
*The others parameters same as Inspect Dot Mode.
X
Y