Smart Gui - Algorithm Training Material_rev1.pdf - 第180页
Copyright © ViT rox All Rights Reserved . U-type Joint- Diff Joint 180 Mode: Inspect Dot 1. Inspection Box Size & Inspection Box Offset ● Interested region to do the inspection. ● T o adjust the inspection box size &…

Copyright © ViTrox All Rights Reserved.
U-type Joint- Diff Joint
179
Mode: Save Image
1. Image Plane
● These are the types of 2D Lighting. Select the one with having highest
contrast among interested inspection region and the background.
2. Box Size & Box Offset
● Interested region to save the base image.
● To adjust the box size & box offset.
3. Search Box Size & Search Box Offset
● Region to search the base image.
● To adjust the search box size & search box offset.
4. Follow Locator
● To enable the inspection boxes follow the locator.
5. Correlation Thres
● This is the correlation threshold.
● Correlation also means as similarity score.
● For e.g. Corr thres set to 750
6. Save Base Image
● Click this icon to save the base image info.
CorrThres
(75%)
PassFail

Copyright © ViTrox All Rights Reserved.
U-type Joint- Diff Joint
180
Mode: Inspect Dot
1. Inspection Box Size & Inspection Box Offset
● Interested region to do the inspection.
● To adjust the inspection box size & inspection box offset
.
2. Bright Thres & Dark Thres
3. Dot Min Size & Big Dot Size
● To define the minimum Dot size & Big Dot size
4. Small Dot Number
● The number of small dot to fail the component
5. Bright/Dark Dot Fail As:
● To define the defects name for each defect detected.
Grey Scale
(Base Image)
Pass
Fail
Dark Thres Bright Thres
Fail

Copyright © ViTrox All Rights Reserved.
U-type Joint- Diff Joint
181
Mode: Inspect Box
1. Box Size X & Box Size Y
● To adjust the size for the auto partitioned joint box
2. Bright Percentage Thres & Dark Percentage Thres
● Box coverage percentage (Within the partition boxes) for bright defect
& dark defect.
*The others parameters same as Inspect Dot Mode.
X
Y