Smart Gui - Algorithm Training Material_rev1.pdf - 第16页
Copyright © ViT rox All Rights Reserved . CR T ype Algorithm - Body 16 1. 3D Geometry Measure ● T ick this to enable the 3D Damaged inspection. ● Consists of minimum/maximum measure for length/width. ● Unit can be in % o…

Copyright © ViTrox All Rights Reserved.
CR Type Algorithm - Body
15
1. 3D Damaged Inspection
● Tick this to enable the 3D Damaged inspection.
● Inspection result will prompt out Coplan if the absolute difference
between the opposite boxes in vertical direction is more
Eg. for 40%
2. Damaged Location
● To adjust the location for the Damaged inspection boxes.
● The smaller the percentage, The inner the boxes towards the
centroid
3. Damaged Thres (um)
● Software will check the height of these 4 boxes, the component
will fail as “Damaged” if the absolute height different between
any one of the ROI's height and component height higher than
damaged threshold.

Copyright © ViTrox All Rights Reserved.
CR Type Algorithm - Body
16
1. 3D Geometry Measure
● Tick this to enable the 3D Damaged inspection.
● Consists of minimum/maximum measure for length/width.
● Unit can be in % or um.
2. Min Length Measure
a. Disable to turn off this inspection.
b. Unit in %
● If Expected component length = 1000um & Min Length Thres set
to 50%
● Fail when Measured Length < 1000um - [1000um*(50/100)]
c. Unit in um
● If Expected component length = 1000um & Min Length Thres set
to 100um
● Fail when Measured Length < 1000um - 100um

Copyright © ViTrox All Rights Reserved.
CR Type Algorithm - Body
17
3. Max Length Measure
a. Disable to off this inspection.
b. Unit in %
● If Expected component length = 1000um & Max Length Thres
set to 50%
● Fail when Measured Length > 1000um + [1000um*(50/100)]
c. Unit in um
● If Expected component length = 1000um & MAx Length Thres
set to 100um