Smart Gui - Algorithm Training Material_rev1.pdf - 第170页
Copyright © ViT rox All Rights Reserved . U-type Locator - CPM 170 a. Box Size & Box Offset ● T o adjust the body size and body offset. b. Image Plane ● These are the types of 2D Lighting. Select the one with having …

Copyright © ViTrox All Rights Reserved.
U-type Locator - Edge Locator
169
1. For U-type Edge Locator, Usually Horizontal & Vertical ruler will used together to locate a component.
2. Another Ruler Orientation can be enabled by select the “+” icon shown below.

Copyright © ViTrox All Rights Reserved.
U-type Locator - CPM
170
a. Box Size & Box Offset
● To adjust the body size and body offset.
b. Image Plane
● These are the types of 2D Lighting. Select the one with having
highest contrast among interested inspection region and the
background.
c. Corr Thres
● This is the correlation threshold.
● Correlation also means as similarity score.
● For e.g. Corr thres set to 750
CorrThres
(75%)
PassFail
d. Horizontal & Vertical Threshold (um)
● Fail when the measured Horizontal & Vertical Offset from datum
exceed the Horizontal & Vertical Thres

Copyright © ViTrox All Rights Reserved.
U-type Locator - CPM
171
e. Enable Rotation
● Tick to enable rotation up to 30 deg
f. Update Offset
● Tick to to update offset
g. Display information
● Tick this to display the Information
h. Corr Failed As
● Select the Error Code prompt out during inspection result fail.
i. Learn CPM
● Click this to learn the template.
j. Find and Append Model