Smart Gui - Algorithm Training Material_rev1.pdf - 第214页
Copyright © ViT rox All Rights Reserved . U-type Algorithm - 3D Multijoint 214 a. Lead Relocating Mode ● Lead relocation is used to relocate the lead by using lead box after locate body successfully . ● This feature will…

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
213
a. Geometry Lock
● To enable the box offset into symmetric direction only.
b. Follow Locator
● Tick this to enable the inspection boxes to follow the body
locator and lead relocation feature.
c. Pad
● Auto: Select this if u have the epad information.
● Manual: Select this to manual add in the pad location.
d. Direction
e. No. of pins
● To define the numbers of inspection boxes for pins.
f. Pitch (um)
● To set the distance between pins.
g. Lead Size & Lead Offset
● To adjust the sizes and the offset for lead inspection boxes.
Horizontal
Vertical

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
214
a. Lead Relocating Mode
● Lead relocation is used to relocate the lead by using lead box
after locate body successfully.
● This feature will increase cycle time.
b. Tip Length (%)
● The lead tip location is always fall at the end of lead box from
the direction body box to lead box
● Tip Length is the selected region to inspect lifted lead and
missing lead

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
215
a. Lead Height (um)
● Lead relocation is used to relocate the lead by using lead box
after locate body successfully.
● This feature will increase cycle time
b. Lifted Lead Inspection
● Relative - Software will calculate the average height for each
lead and used it as the reference height for lifted lead
inspection.
● Absolute - Lead Height (um) that we keyin will be used as the
reference height for lifted lead inspection.