Smart Gui - Algorithm Training Material_rev1.pdf - 第214页

Copyright © ViT rox All Rights Reserved . U-type Algorithm - 3D Multijoint 214 a. Lead Relocating Mode ● Lead relocation is used to relocate the lead by using lead box after locate body successfully . ● This feature will…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
213
a. Geometry Lock
To enable the box offset into symmetric direction only.
b. Follow Locator
Tick this to enable the inspection boxes to follow the body
locator and lead relocation feature.
c. Pad
Auto: Select this if u have the epad information.
Manual: Select this to manual add in the pad location.
d. Direction
e. No. of pins
To define the numbers of inspection boxes for pins.
f. Pitch (um)
To set the distance between pins.
g. Lead Size & Lead Offset
To adjust the sizes and the offset for lead inspection boxes.
Horizontal
Vertical
Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
214
a. Lead Relocating Mode
Lead relocation is used to relocate the lead by using lead box
after locate body successfully.
This feature will increase cycle time.
b. Tip Length (%)
The lead tip location is always fall at the end of lead box from
the direction body box to lead box
Tip Length is the selected region to inspect lifted lead and
missing lead
Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
215
a. Lead Height (um)
Lead relocation is used to relocate the lead by using lead box
after locate body successfully.
This feature will increase cycle time
b. Lifted Lead Inspection
Relative - Software will calculate the average height for each
lead and used it as the reference height for lifted lead
inspection.
Absolute - Lead Height (um) that we keyin will be used as the
reference height for lifted lead inspection.