Smart Gui - Algorithm Training Material_rev1.pdf - 第60页

Copyright © ViT rox All Rights Reserved . 60 P ASS F AIL F AIL Expected Component Length - Min Thres (um/%) Expected Component Length + Max Thres (um/%) Software measured length in within this range will pass and out of …

100%1 / 331
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
59
3. Max Length Measure
a. Disable to off this inspection.
b. Unit in %
If Expected component length = 1000um & Max Length Thres
set to 50%
Fail when Measured Length > 1000um + [1000um*(50/100)]
c. Unit in um
If Expected component length = 1000um & MAx Length Thres
set to 100um
Fail when Measured Length > 1000um + 100um
Copyright © ViTrox All Rights Reserved.
60
PASS FAILFAIL
Expected Component Length - Min Thres (um/%) Expected Component Length + Max Thres (um/%)
Software measured length in
within this range will pass
and out of this range will fail.
B-type Algorithm - Body
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
61
3. Min Width Measure
Same as Min Length Measure
Refer figure below for length & width definition.
4. Max Width Measure
Same as Max Length Measure
Refer figure below for length & width definition.
Length
Width