Smart Gui - Algorithm Training Material_rev1.pdf - 第60页
Copyright © ViT rox All Rights Reserved . 60 P ASS F AIL F AIL Expected Component Length - Min Thres (um/%) Expected Component Length + Max Thres (um/%) Software measured length in within this range will pass and out of …

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
59
3. Max Length Measure
a. Disable to off this inspection.
b. Unit in %
● If Expected component length = 1000um & Max Length Thres
set to 50%
● Fail when Measured Length > 1000um + [1000um*(50/100)]
c. Unit in um
● If Expected component length = 1000um & MAx Length Thres
set to 100um
● Fail when Measured Length > 1000um + 100um

Copyright © ViTrox All Rights Reserved.
60
PASS FAILFAIL
Expected Component Length - Min Thres (um/%) Expected Component Length + Max Thres (um/%)
Software measured length in
within this range will pass
and out of this range will fail.
B-type Algorithm - Body

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
61
3. Min Width Measure
● Same as Min Length Measure
● Refer figure below for length & width definition.
4. Max Width Measure
● Same as Max Length Measure
● Refer figure below for length & width definition.
Length
Width