Smart Gui - Algorithm Training Material_rev1.pdf - 第64页
Copyright © ViT rox All Rights Reserved . 64 B-type Algorithm - Joint 1. Pad Mode ● Auto: Select this if you have epad & epin informations. ● Manual: Select this to self define the pad location. 2. Lead Direction ● T…

Copyright © ViTrox All Rights Reserved.
63
Joint Inspection Algorithm

Copyright © ViTrox All Rights Reserved.
64
B-type Algorithm - Joint
1. Pad Mode
● Auto: Select this if you have epad & epin informations.
● Manual: Select this to self define the pad location.
2. Lead Direction
● To select the direction for lead .
● Either in horizontal or vertical.
3. Number of Leads
● To define the number of lead.
4. Lead Pitch
● To define the distance between 2 leads.
5. Lead Relocation
● Lead relocation is used to relocate the lead by using lead box
after locate body successfully.
● This feature will increase cycle time..

Copyright © ViTrox All Rights Reserved.
65
B-type Algorithm - Joint
6. Tip Length (%)
● The lead tip location is always fall at the end of lead box from
the direction body box to lead box
● Tip Length is the selected region to inspect lifted lead and
missing lead