Smart Gui - Algorithm Training Material_rev1.pdf - 第64页

Copyright © ViT rox All Rights Reserved . 64 B-type Algorithm - Joint 1. Pad Mode ● Auto: Select this if you have epad & epin informations. ● Manual: Select this to self define the pad location. 2. Lead Direction ● T…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
63
Joint Inspection Algorithm
Copyright © ViTrox All Rights Reserved.
64
B-type Algorithm - Joint
1. Pad Mode
Auto: Select this if you have epad & epin informations.
Manual: Select this to self define the pad location.
2. Lead Direction
To select the direction for lead .
Either in horizontal or vertical.
3. Number of Leads
To define the number of lead.
4. Lead Pitch
To define the distance between 2 leads.
5. Lead Relocation
Lead relocation is used to relocate the lead by using lead box
after locate body successfully.
This feature will increase cycle time..
Copyright © ViTrox All Rights Reserved.
65
B-type Algorithm - Joint
6. Tip Length (%)
The lead tip location is always fall at the end of lead box from
the direction body box to lead box
Tip Length is the selected region to inspect lifted lead and
missing lead