Copyright © ViT rox All Rights Reserved . CR T ype Algorithm - Body 15 1. 3D Damaged Inspection ● T ick this to enable the 3D Damaged inspection. ● Inspection result will prompt out Coplan if the absolute difference betw…

Copyright © ViTrox All Rights Reserved.
CR Type Algorithm - Body
14
1. Coplan Vert Thres (um)
● Tick this to enable the vertical direction for coplan inspection.
● Inspection result will prompt out Coplan if the absolute difference
between the opposite boxes in vertical direction is more than the
threshold set.
2. Coplan Horiz Thres (um)
● Tick this to enable the horizontal direction for coplan inspection.
● Inspection result will prompt out Coplan if the absolute difference
between the opposite boxes in horizontal direction is more than
the threshold set.
Coplan Thres (um)
Pass
Fail

Copyright © ViTrox All Rights Reserved.
CR Type Algorithm - Body
15
1. 3D Damaged Inspection
● Tick this to enable the 3D Damaged inspection.
● Inspection result will prompt out Coplan if the absolute difference
between the opposite boxes in vertical direction is more
Eg. for 40%
2. Damaged Location
● To adjust the location for the Damaged inspection boxes.
● The smaller the percentage, The inner the boxes towards the
centroid
3. Damaged Thres (um)
● Software will check the height of these 4 boxes, the component
will fail as “Damaged” if the absolute height different between
any one of the ROI's height and component height higher than
damaged threshold.

Copyright © ViTrox All Rights Reserved.
CR Type Algorithm - Body
16
1. 3D Geometry Measure
● Tick this to enable the 3D Damaged inspection.
● Consists of minimum/maximum measure for length/width.
● Unit can be in % or um.
2. Min Length Measure
a. Disable to turn off this inspection.
b. Unit in %
● If Expected component length = 1000um & Min Length Thres set
to 50%
● Fail when Measured Length < 1000um - [1000um*(50/100)]
c. Unit in um
● If Expected component length = 1000um & Min Length Thres set
to 100um
● Fail when Measured Length < 1000um - 100um