Smart Gui - Algorithm Training Material_rev1.pdf - 第29页
Copyright © ViT rox All Rights Reserved . 29 1. Solder V olume 2D+3D ● Using 2D (Grayscale) and 3D(Height) ● OR Relation between 2D and 3D as pass criteria ● Every single pixels in the joint box will go through inspectio…

Copyright © ViTrox All Rights Reserved.
28
CR Type Algorithm - Joint (2D Only)
5. Joint Coverage Threshold
● Using 2D only (Grayscale)
● Every single pixels in the joint box will go through inspection.
● The pixels highlighted in purple colour is the passed pixels that
(Grayscale on that pixel < Gray Thres set).
● The number in yellow beside the joint box is the percentage of
pass pixels. Refer to example below.

Copyright © ViTrox All Rights Reserved.
29
1. Solder Volume 2D+3D
● Using 2D (Grayscale) and 3D(Height)
● OR Relation between 2D and 3D as pass criteria
● Every single pixels in the joint box will go through inspection
CR Type Algorithm - Joint (Solder Volume 2D+3D)

Copyright © ViTrox All Rights Reserved.
30
1. Solder Coverage 2D+3D (um)
● Same as Solder Coverage 2D+3D (%)
● Except the height unit in um.
● The height thres will increased when lifted body happened.
● Below shows 2 examples with height Threshold: 80um at
different conditions:
a. Without Lifted body
b. With Lifted body
CR Type Algorithm - Joint [Solder Coverage 2D+3D (um)]
Pass Criteria for single pixel:
a. Measured Grayscale < Joint Grey Thres
b. Solder Height (%) > Joint Height Thres (%).
The overall pass criteria depends on:
Joint Coverage (%) > Joint Coverage Thres (%)
where,