Smart Gui - Algorithm Training Material_rev1.pdf - 第58页
Copyright © ViT rox All Rights Reserved . B-type Algorithm - Body 58 1. 3D Geometry Measure ● T ick this to enable the 3D Damaged inspection. ● Consists of minimum/maximum measure for length/width. ● Unit can be in % or …

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
57
h. 3D Damaged Inspection
● Tick this to enable 3D Damaged Inspection
i. Damaged Location
● To adjust the location for the damages inspection boxes.
● The smaller the percentage, The inner the boxes towards the centroid
j. Damaged Thres
● Software will check the height of these 4 boxes, the component will fail as
“Damaged” if the absolute height different between any one of the ROI's height
and component height higher than damaged threshold.
Damaged Thres (um)
Measured Height - Reference Height
FAIL
PASS

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
58
1. 3D Geometry Measure
● Tick this to enable the 3D Damaged inspection.
● Consists of minimum/maximum measure for length/width.
● Unit can be in % or um.
2. Min Length Measure
a. Disable to off this inspection.
b. Unit in %
● If Expected component length = 1000um & Min Length Thres set
to 50%
● Fail when Measured Length < 1000um - [1000um*(50/100)]
c. Unit in um
● If Expected component length = 1000um & Min Length Thres set
to 100um
● Fail when Measured Length < 1000um - 100um

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
59
3. Max Length Measure
a. Disable to off this inspection.
b. Unit in %
● If Expected component length = 1000um & Max Length Thres
set to 50%
● Fail when Measured Length > 1000um + [1000um*(50/100)]
c. Unit in um
● If Expected component length = 1000um & MAx Length Thres
set to 100um
● Fail when Measured Length > 1000um + 100um