Copyright © ViT rox All Rights Reserved . B-type Algorithm - Body 58 1. 3D Geometry Measure ● T ick this to enable the 3D Damaged inspection. ● Consists of minimum/maximum measure for length/width. ● Unit can be in % or …

100%1 / 331
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
57
h. 3D Damaged Inspection
Tick this to enable 3D Damaged Inspection
i. Damaged Location
To adjust the location for the damages inspection boxes.
The smaller the percentage, The inner the boxes towards the centroid
j. Damaged Thres
Software will check the height of these 4 boxes, the component will fail as
“Damaged” if the absolute height different between any one of the ROI's height
and component height higher than damaged threshold.
Damaged Thres (um)
Measured Height - Reference Height
FAIL
PASS
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
58
1. 3D Geometry Measure
Tick this to enable the 3D Damaged inspection.
Consists of minimum/maximum measure for length/width.
Unit can be in % or um.
2. Min Length Measure
a. Disable to off this inspection.
b. Unit in %
If Expected component length = 1000um & Min Length Thres set
to 50%
Fail when Measured Length < 1000um - [1000um*(50/100)]
c. Unit in um
If Expected component length = 1000um & Min Length Thres set
to 100um
Fail when Measured Length < 1000um - 100um
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
59
3. Max Length Measure
a. Disable to off this inspection.
b. Unit in %
If Expected component length = 1000um & Max Length Thres
set to 50%
Fail when Measured Length > 1000um + [1000um*(50/100)]
c. Unit in um
If Expected component length = 1000um & MAx Length Thres
set to 100um
Fail when Measured Length > 1000um + 100um