Smart Gui - Algorithm Training Material_rev1.pdf - 第175页

Copyright © ViT rox All Rights Reserved . U-type Locator - M Joint 175 a. Direction ● Tick to enable the joint inspection box follow locator . b. Count ● T o adjust the number of pin. c. Pitch ● T o adjust the distance b…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
U-type Locator - Single Joint
174
Pass Criteria for single pixel:
a. Measured Grayscale < Joint Grey Thres
The overall pass criteria depends on:
Joint Coverage (%) > Joint Coverage Thres (%)
where,
g. Joint Coverage Thres
h. Joint Fail As
Select the Error Code prompt out during inspection result fail.
Joint Coverage Threshold
Pass
Fail
Copyright © ViTrox All Rights Reserved.
U-type Locator - M Joint
175
a. Direction
Tick to enable the joint inspection box follow locator.
b. Count
To adjust the number of pin.
c. Pitch
To adjust the distance between the pins.
d. Pin Number
To define the pin number
e. Inverse Pin Numbering
To inverse the pin numbering.
f. Box Size & Box Offset
To adjust the joint inspection box size & joint inspection box offset.
g. Image Plane
These are the types of 2D Lighting. Select the one with having
highest contrast among interested inspection region and the
background.
h. Grey Thres
i. Invert Grey Thres
Invert the Grey Thres Logic
Dark: Fail & Bright: Pass
Grey Threshold
Pass Fail
Pass Criteria for single pixel:
a. Measured Grayscale < Joint Grey Thres
The overall pass criteria depends on:
Joint Coverage (%) > Joint Coverage Thres (%)
where,
Copyright © ViTrox All Rights Reserved.
176
U-Type Diff Joint Algorithm
Identify surface defects on component using certain parameter and
through learning good components