Copyright © ViT rox All Rights Reserved . U-type Algorithm - 3D Multijoint 217 1. Solder Inspection ● Solder Inspection consists of 3 mode. Which are: T erminal Reference : Solder height qualification are based on the he…

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
216
a. Lifted Lead Threshold (um) & Missing Lead Threshold (um)
Lead Height
Measured
Lead Height
-
Missing Lead
Thres
Lead Height
+
Lifted Lead
Thres
Pass
Fail
(Lifted Lead)
Fail
(Missing Lead)

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
217
1. Solder Inspection
● Solder Inspection consists of 3 mode. Which are:
Terminal Reference: Solder height qualification are based on the
height (%) between lead terminal & PCB surface
Base Reference: Solder height qualification are based on the height
(um) measured from PCB surface

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint (Base Reference)
218
Base Reference
a. Joint Size & Joint Offset
● To adjust the sizes and the offset for joint inspection boxes
b. Joint Image Plane
● These are the types of 2D Lighting. Select the one with having highest
contrast among interested inspection region and the background.
● Usually choose angle 2+3
c. Joint Grey Thres
● Usually set to 160
d. Joint Height Thres
e. Joint Coverage Thres(%)
● To set the percentage to pass the joint inspection.
Grey Thres
Measured Grey Thres
PASS FAIL
Height Thres (um)
Measured Height (um)
Fail Pass
Pass Criteria for single pixel:
a. Measured Grayscale < Joint Grey Thres
b. Solder Height (%) > Joint Height Thres (%).
The overall pass criteria depends on:
Joint Coverage (%) > Joint Coverage Thres (%)
where,