Smart Gui - Algorithm Training Material_rev1.pdf - 第80页

Copyright © ViT rox All Rights Reserved . 80 a. Exposed Copper Inspection ● Enable or Disable Exposed Copper Inspection b. Exposed Copper Grey Threshold ● Grey T reshold for exposed copper c. Exposed Copper Coverage Thre…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
79
a. Slope Profile
Enable or Disable Slope Profile Inspection.
b. Slope Position
Location for slope profile inspection
c. Slope Toe Image Plane
These are the types of 2D Lighting. Select the one with having
highest contrast among interested inspection region and the
background.
d. Slope Toe Grey Thres
2D Gray threshold to decide if there is excess solder at Toe area
e. Slope Toe Height
Height threshold from PCB surface, to decide if there is solder at toe
area
f. Slope Toe Coverage Thres
Threshold to qualify the coverage of solder at toe area
g. Slope Solder Height Thres
Height threshold to qualify Solder Height Inspection
B-type Algorithm - Joint (Solder Profile Inspection)
Copyright © ViTrox All Rights Reserved.
80
a. Exposed Copper Inspection
Enable or Disable Exposed Copper Inspection
b. Exposed Copper Grey Threshold
Grey Treshold for exposed copper
c. Exposed Copper Coverage Threshold (%)
Threshold to fail exposed copper by Area of Coverage
Exposed Copper Gray
Threshold
Pass Fail
(Exposed Copper)
Exposed Copper
Coverage Threshold
Pass Fail
B-type Algorithm - Joint (Exposed Copper)
Copyright © ViTrox All Rights Reserved.
81
Joint Bridging Inspection