Copyright © ViT rox All Rights Reserved . U-type Algorithm - 2D Multi Joint 210 a. Geometry Lock ● T o enable the box offset into symmetric direction only . b. Follow Locator ● Tick to enable the joint inspection box fol…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
209
Multi-Joint Inspection Algorithm
Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 2D Multi Joint
210
a. Geometry Lock
To enable the box offset into symmetric direction only.
b. Follow Locator
Tick to enable the joint inspection box follow locator.
c. Pad
Tick this to define the pad location.
d. Pad Size & Pad Offset
To adjust the Pad size and pad offset.
e. Direction
f. No of Pins
To adjust the number of pin.
g. Pitch
To adjust the distance between the pins.
h. Lead Size and Lead Offset
To adjust the Lead inspection box size & Lead inspection box offset.
Horizontal
Vertical
Copyright © ViTrox All Rights Reserved.
a. Solder Inspection
To enable the box offset into symmetric direction only.
b. Joint Size & Joint Offset
To adjust the size of Joint Inspection Box & offset of Joint Inspection
Box.
c. Joint Image Plane
These are the types of 2D Lighting. Select the one with having
highest contrast among pin region and the background.
d. Joint Grey Thres
e. Joint Coverage Thres
To set the percentage to pass the joint inspection.
U-type Algorithm - 2D Multi Joint
211
Grey Thres
Measured Grey Thres
PASS FAIL
Pass Criteria for single pixel:
a. Measured Grayscale < Joint Grey Thres
b. Solder Height (%) > Joint Height Thres (%).
The overall pass criteria depends on:
Joint Coverage (%) > Joint Coverage Thres (%)
where,