Smart Gui - Algorithm Training Material_rev1.pdf - 第213页

Copyright © ViT rox All Rights Reserved . U-type Algorithm - 3D Multijoint 213 a. Geometry Lock ● T o enable the box offset into symmetric direction only . b. Follow Locator ● Tick this to enable the inspection boxes to …

100%1 / 331
Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 2D Multi Joint
212
a. Bridge Inspection
Tick this to enable the Bridge Inspection.
b. Bridge Size & Bridge Offset
To adjust the size of Bridge Inspection Box & offset of Bridge
Inspection Box
c. Bridge Follow Locator
Tick this to enable the Bridge Inspection Box to follow the locator.
d. Bridge Image Plane
These are the types of 2D Lighting. Select the one with having
highest contrast among pin region and the background.
e. 2D Bridge Grey Thres
f. 2D Bridge Width Percent
To set the width percentage to fail the Bridging Inspection
2D Bridge Gray
Threshold
Pass Fail
Width
Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
213
a. Geometry Lock
To enable the box offset into symmetric direction only.
b. Follow Locator
Tick this to enable the inspection boxes to follow the body
locator and lead relocation feature.
c. Pad
Auto: Select this if u have the epad information.
Manual: Select this to manual add in the pad location.
d. Direction
e. No. of pins
To define the numbers of inspection boxes for pins.
f. Pitch (um)
To set the distance between pins.
g. Lead Size & Lead Offset
To adjust the sizes and the offset for lead inspection boxes.
Horizontal
Vertical
Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
214
a. Lead Relocating Mode
Lead relocation is used to relocate the lead by using lead box
after locate body successfully.
This feature will increase cycle time.
b. Tip Length (%)
The lead tip location is always fall at the end of lead box from
the direction body box to lead box
Tip Length is the selected region to inspect lifted lead and
missing lead