Smart Gui - Algorithm Training Material_rev1.pdf - 第213页
Copyright © ViT rox All Rights Reserved . U-type Algorithm - 3D Multijoint 213 a. Geometry Lock ● T o enable the box offset into symmetric direction only . b. Follow Locator ● Tick this to enable the inspection boxes to …

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 2D Multi Joint
212
a. Bridge Inspection
● Tick this to enable the Bridge Inspection.
b. Bridge Size & Bridge Offset
● To adjust the size of Bridge Inspection Box & offset of Bridge
Inspection Box
c. Bridge Follow Locator
● Tick this to enable the Bridge Inspection Box to follow the locator.
d. Bridge Image Plane
● These are the types of 2D Lighting. Select the one with having
highest contrast among pin region and the background.
e. 2D Bridge Grey Thres
f. 2D Bridge Width Percent
● To set the width percentage to fail the Bridging Inspection
2D Bridge Gray
Threshold
Pass Fail
Width

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
213
a. Geometry Lock
● To enable the box offset into symmetric direction only.
b. Follow Locator
● Tick this to enable the inspection boxes to follow the body
locator and lead relocation feature.
c. Pad
● Auto: Select this if u have the epad information.
● Manual: Select this to manual add in the pad location.
d. Direction
e. No. of pins
● To define the numbers of inspection boxes for pins.
f. Pitch (um)
● To set the distance between pins.
g. Lead Size & Lead Offset
● To adjust the sizes and the offset for lead inspection boxes.
Horizontal
Vertical

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Multijoint
214
a. Lead Relocating Mode
● Lead relocation is used to relocate the lead by using lead box
after locate body successfully.
● This feature will increase cycle time.
b. Tip Length (%)
● The lead tip location is always fall at the end of lead box from
the direction body box to lead box
● Tip Length is the selected region to inspect lifted lead and
missing lead