Smart Gui - Algorithm Training Material_rev1.pdf - 第173页
Copyright © ViT rox All Rights Reserved . U-type Locator - Single Joint 173 a. Follow Locator ● Tick to enable the joint inspection box follow locator . b. Pin Number ● T o adjust the number of pin. c. Box Size & Box…

Copyright © ViTrox All Rights Reserved.
172
Single Joint Inspection Algorithm

Copyright © ViTrox All Rights Reserved.
U-type Locator - Single Joint
173
a. Follow Locator
● Tick to enable the joint inspection box follow locator.
b. Pin Number
● To adjust the number of pin.
c. Box Size & Box Offset
● To adjust the joint inspection box size & joint inspection box offset.
d. Image Plane
● These are the types of 2D Lighting. Select the one with having
highest contrast among interested inspection region and the
background.
e. Grey Thres
f. Invert Grey Thres
Grey Threshold
Pass Fail
Grey Threshold
PassFail

Copyright © ViTrox All Rights Reserved.
U-type Locator - Single Joint
174
Pass Criteria for single pixel:
a. Measured Grayscale < Joint Grey Thres
The overall pass criteria depends on:
Joint Coverage (%) > Joint Coverage Thres (%)
where,
g. Joint Coverage Thres
h. Joint Fail As
● Select the Error Code prompt out during inspection result fail.
Joint Coverage Threshold
Pass
Fail