Copyright © ViT rox All Rights Reserved . S-T ype Algorithm - Joint Inspection (Coverage) 1 17 1. Joint Size & Joint Offset ● T o adjust the sizes and the offset for joint inspection boxes 2. Joint Image Plane ● Thes…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
S-Type Algorithm - Joint Inspection
116
3. Lifted Thres (um) & Missing Thres (um)
Reference
Lead Height
Lead Height
-
Missing Lead
Thres
Lead Height
+
Lifted Lead
Thres
Pass
Fail
(Lifted Lead)
Fail
(Missing Lead)
4. Tip Length (%)
The lead tip location is always fall at the end of lead box from
the direction body box to lead box
Tip Length is the selected region to inspect lifted lead and
missing lead.
Copyright © ViTrox All Rights Reserved.
S-Type Algorithm - Joint Inspection (Coverage)
117
1. Joint Size & Joint Offset
To adjust the sizes and the offset for joint inspection boxes
2. Joint Image Plane
These are the types of 2D Lighting. Select the one with having highest
contrast among interested inspection region and the background.
Usually choose angle 2+3
3. Joint Follow Locator
Tick this to enable the joint inspection ROI follow the locator.
4. Joint Grey Thres
Usually set to 160
4. Joint Height Thres
5. Joint Coverage Thres(%)
To set the percentage to pass the joint inspection.
Grey Thres
Measured Grey Thres
PASS
FAIL
Height Thres (um)
Measured Height(um)
PASS
FAIL
Copyright © ViTrox All Rights Reserved.
S-type Algorithm - Joint (Solder Profile Inspection)
1. Solder Profile Inspection consists of 2 main function as below:
Fillet Solder: To inspect insufficient solder
Solder Profile: To detect cold solder
118
Cold Solder