Smart Gui - Algorithm Training Material_rev1.pdf - 第117页
Copyright © ViT rox All Rights Reserved . S-T ype Algorithm - Joint Inspection (Coverage) 1 17 1. Joint Size & Joint Offset ● T o adjust the sizes and the offset for joint inspection boxes 2. Joint Image Plane ● Thes…

Copyright © ViTrox All Rights Reserved.
S-Type Algorithm - Joint Inspection
116
3. Lifted Thres (um) & Missing Thres (um)
Reference
Lead Height
Lead Height
-
Missing Lead
Thres
Lead Height
+
Lifted Lead
Thres
Pass
Fail
(Lifted Lead)
Fail
(Missing Lead)
4. Tip Length (%)
● The lead tip location is always fall at the end of lead box from
the direction body box to lead box
● Tip Length is the selected region to inspect lifted lead and
missing lead.

Copyright © ViTrox All Rights Reserved.
S-Type Algorithm - Joint Inspection (Coverage)
117
1. Joint Size & Joint Offset
● To adjust the sizes and the offset for joint inspection boxes
2. Joint Image Plane
● These are the types of 2D Lighting. Select the one with having highest
contrast among interested inspection region and the background.
● Usually choose angle 2+3
3. Joint Follow Locator
● Tick this to enable the joint inspection ROI follow the locator.
4. Joint Grey Thres
● Usually set to 160
4. Joint Height Thres
5. Joint Coverage Thres(%)
● To set the percentage to pass the joint inspection.
Grey Thres
Measured Grey Thres
PASS
FAIL
Height Thres (um)
Measured Height(um)
PASS
FAIL

Copyright © ViTrox All Rights Reserved.
S-type Algorithm - Joint (Solder Profile Inspection)
1. Solder Profile Inspection consists of 2 main function as below:
• Fillet Solder: To inspect insufficient solder
• Solder Profile: To detect cold solder
118
Cold Solder