Smart Gui - Algorithm Training Material_rev1.pdf - 第54页
Copyright © ViT rox All Rights Reserved . B-type Algorithm - Body 54 a. Component Height ● T o set a reference height for the component. ● Any body defects inspection will based on this reference to made the calculation.…

Copyright © ViTrox All Rights Reserved.
53
Body Inspection Algorithm

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
54
a. Component Height
● To set a reference height for the component.
● Any body defects inspection will based on this reference to
made the calculation.
● User can obtain the component by “3D mode” or right click on
the component body and select update body height.
b. Missing Location
● To select the location to inspect missing defect.
Center Terminal Custom
Can set the region.
c. Missing Threshold
Missing Thres (um)
Measured Height (um)
FAIL PASS

Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
55
d. Coplan Mode
● To select the arrangement of the inspection boxes to detect
coplanarity defects.
3. Coplan Alternative
● Add another AND relationship coplan alternative which different
in the coplan location.
Both Primary and Alternative
must pass in order to pass
Cross Square
e. Coplan Thres
● To enable the coplan inspection direction in horizontal or vertical
or both.
Eg. for 40%
f. Coplan Location
● To adjust the location for the coplan inspection boxes.
● The smaller the percentage, The inner the boxes towards the
centroid