Smart Gui - Algorithm Training Material_rev1.pdf - 第54页

Copyright © ViT rox All Rights Reserved . B-type Algorithm - Body 54 a. Component Height ● T o set a reference height for the component. ● Any body defects inspection will based on this reference to made the calculation.…

100%1 / 331
Copyright © ViTrox All Rights Reserved.
53
Body Inspection Algorithm
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
54
a. Component Height
To set a reference height for the component.
Any body defects inspection will based on this reference to
made the calculation.
User can obtain the component by “3D mode” or right click on
the component body and select update body height.
b. Missing Location
To select the location to inspect missing defect.
Center Terminal Custom
Can set the region.
c. Missing Threshold
Missing Thres (um)
Measured Height (um)
FAIL PASS
Copyright © ViTrox All Rights Reserved.
B-type Algorithm - Body
55
d. Coplan Mode
To select the arrangement of the inspection boxes to detect
coplanarity defects.
3. Coplan Alternative
Add another AND relationship coplan alternative which different
in the coplan location.
Both Primary and Alternative
must pass in order to pass
Cross Square
e. Coplan Thres
To enable the coplan inspection direction in horizontal or vertical
or both.
Eg. for 40%
f. Coplan Location
To adjust the location for the coplan inspection boxes.
The smaller the percentage, The inner the boxes towards the
centroid