Smart Gui - Algorithm Training Material_rev1.pdf - 第198页
Copyright © ViT rox All Rights Reserved . 198 Ringer *Refer S-T ype Ringer

Copyright © ViTrox All Rights Reserved.
197
3D Height Inspection

Copyright © ViTrox All Rights Reserved.
198
Ringer
*Refer S-Type Ringer

Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Cross Section
199
a. Follow Locator
● Follows locator is used to follow the body locator and lead relocation
feature.
b. Box Size & Box Offset
● To adjust the size of Inspection Box & offset of Inspection Box.
c. Threshold
● Threshold is used to set the pass criteria regarding to the height
value for inspection at the selected region. After inspection, the pixel
will contain the height value.
d. Pass Criteria
● Pass Criteria is used to set the criteria for the inspection to pass.
There are 2 types of pass criteria:
➢ All height below the TH
➢ At least one height above TH
e. Fail As
● Used to set defect name when this algorithm fail.