Smart Gui - Algorithm Training Material_rev1.pdf - 第198页

Copyright © ViT rox All Rights Reserved . 198 Ringer *Refer S-T ype Ringer

100%1 / 331
Copyright © ViTrox All Rights Reserved.
197
3D Height Inspection
Copyright © ViTrox All Rights Reserved.
198
Ringer
*Refer S-Type Ringer
Copyright © ViTrox All Rights Reserved.
U-type Algorithm - 3D Cross Section
199
a. Follow Locator
Follows locator is used to follow the body locator and lead relocation
feature.
b. Box Size & Box Offset
To adjust the size of Inspection Box & offset of Inspection Box.
c. Threshold
Threshold is used to set the pass criteria regarding to the height
value for inspection at the selected region. After inspection, the pixel
will contain the height value.
d. Pass Criteria
Pass Criteria is used to set the criteria for the inspection to pass.
There are 2 types of pass criteria:
All height below the TH
At least one height above TH
e. Fail As
Used to set defect name when this algorithm fail.