00198661-02_UM_SX12-V3_EN.pdf - 第104页
3 Technical data and assemblies I nstruction manual SIPLACE SX1/S X2 Edition V2 and V3 3.1 Performance data for the SIPLACE SX1/SX2 V3 From software ve rsion SC.713.1 Edition 12/2020 104 3.1.2 PCB conveyor - dat a Single…

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 3 Technical data and assemblies
From software version SC.713.1 Edition 12/2020 3.1 Performance data for the SIPLACE SX1/SX2 V3
103
3 Technical data and assemblies
3.1 Performance data for the SIPLACE SX1/SX2 V3
3.1.1 Machine performance
3
Placement head types SIPLACE SpeedStar (C&P20 P2)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
Placement performance
The placement performance is influenced by the different head combinations and head positions, plus the conveyor
configurations. Individual options and customized applications also influence the placement performance. On request,
SIPLACE can calculate the actual performance of your product on your machine configuration.
IPC value [components/h]
According to the vendor-neutral conditions of the IPC 9850 standard published by the Association of Connecting Elec-
tronics Industries.
SIPLACE benchmark value [components/h]
The SIPLACE benchmark value is measured during the machine acceptance tests. It corresponds to the conditions set
out in the SIPLACE scope of service and supply.
SIPLACE SX2 placement
machine
Placement area IPC value Benchmark value
C&P20 P2 / C&P20 P2 66,000 86,500
C&P20 P2 / CPP
*a
52,500 66,000
CPP
b
/ CPP
b
38,000 46,000
*b
CPP / TH 23,100 27,000
TH / TH 10,200 11,000
SIPLACE SX1 placement
machine
Placement area IPC value Benchmark value
C&P20 P2 33,000 43,000
CPP
a
19,000 23,000
TH 5,100 5,500
*)a MultiStar CPP: low installation position
*)b MultiStar CPP: high installation position

3 Technical data and assemblies Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
3.1 Performance data for the SIPLACE SX1/SX2 V3 From software version SC.713.1 Edition 12/2020
104
3.1.2 PCB conveyor - data
Single conveyor Flexible dual con-
veyor
Dual conveyor in single
conveyor mode
Standard dimensions
(length x width)
50 mm x 50 mm to
450 mm x 560 mm
50 mm x 50 mm to
450 mm x 265 mm
50 mm x 50 mm to
450 mm x 460 mm
Dimensions with “Long
Board”option (length x width) 50 mm x 50 mm to
1525 mm
*a
x 560 mm
50 mm x 50 mm to
850 mm x 265 mm
50 mm x 50 mm to
850 mm x 460 mm
Stationary conveyor side Right, left or outer
Automatic electrical width adjust-
ment
Standard
PCB thickness
Standard
"Thick board" option
0.3 mm to 4.5 mm
2.0 mm to 6.5 mm
Clamping length of board 450 mm
Space for positioning support pins 440 mm
PCB warpage See page 151
PCB weight
*b
Max. 3.0 kg Max. 2.0 kg Max. 2.0 kg
Clearance on PCB underside 25 mm
PCB conveyor height
Option
Standard
Option SMEMA
900 mm
930 mm
950 mm
Type of interface SMEMA or IPC-HERMES-9852
Component-free PCB handling
edge
3 mm
PCB changeover time
Single conveyor
Dual conveyor
*c
< 1.5 seconds
0 seconds
*)a With input/output conveyor only
*)b The board weight value refers to the weight of the board plus the weight of the components.
*)c 0 seconds in asynchronous mode, otherwise 1.5 seconds.
Important notes
When setting up a machine (S; F-, HS-, HF-, X- or D-Series) next to a SIPLACE SX, be aware that there is limited room between the two
machines. In these cases, use suitable conveyor extensions to create room of 0.5m for the operator between the two machines.

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 3 Technical data and assemblies
From software version SC.713.1 Edition 12/2020 3.2 Performance data for the SIPLACE SX1/SX2 V2
105
3.2 Performance data for the SIPLACE SX1/SX2 V2
3.2.1 Machine performance
3
Placement head types SIPLACE SpeedStar (C&P20 P)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
Placement performance
The placement performance is influenced by the different head combinations and head positions, plus the conveyor
configurations. Individual options and customized applications also influence the placement performance. On
request, ASM can calculate the actual performance of your product on your machine configuration.
IPC value [components/h]
According to the vendor-neutral conditions of the IPC 9850 standard published by the Association of Connecting
Electronics Industries.
SIPLACE benchmark value [components/h]
The SIPLACE benchmark value is measured during the machine acceptance tests. It corresponds to the conditions
set out in the ASM scope of service and supply.
SIPLACE SX2 placement
machine
Placement area IPC value Benchmark value
C&P20 P / C&P20 P 59,000 74,000
C&P20 P / CPP
*a
48,000 60,000
CPP
b
/ CPP
b
38,000 46,000
*b
CPP / TH 23,100 27,000
TH / TH 10,200 11,000
SIPLACE SX1 placement
machine
Placement area IPC value Benchmark value
C&P20 P 29,500 37,000
CPP
a
19,000 23,000
TH 5,100 5,500
*)a MultiStar CPP: low installation position
*)b MultiStar CPP: high installation position