00198661-02_UM_SX12-V3_EN.pdf - 第311页

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 6 Station e xtensi ons From software version SC.713.1 Edition 12/2020 6.4 Waffle pack ch anger (WPC5/WPC6) 311 6.4.5 T echnical data 6.4.5.1 Dimensions, weight 6 WPC5/…

100%1 / 366
6 Station extensions Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
6.4 Waffle pack changer (WPC5/WPC6) From software version SC.713.1 Edition 12/2020
310
6.4.3 Safety instructions
6
6
6
6.4.4 Notes on operation
6
6.4.4.1 Operation, maintenance, service
For detailed documentation of the operation, maintenance and servicing of the waffle pack
changer, refer to the manuals supplied with your waffle pack changer.
WARNING
Risk of injuries!
Risk of injuries at the waffle pack changer when the placement machine is running.
Do not reach into the gaps between the waffle pack changer and the machine base
while the placement machine is running.
WARNING
Requirement for operation: Docking the waffle pack changer onto the placement ma-
chine!
The waffle pack changer may NOT be operated unless it is docked onto the placement
machine.
Only connect/disconnect the control cable for the waffle pack changer to/from the
connection socket when the waffle pack changer is docked onto the placement ma-
chine.
Only connect/disconnect the power supply cable to/from the external power supply if
the waffle pack changer is docked onto the placement machine.
PLEASE NOTE
Observe the order of switching on
If there are two waffle pack changers installed at one placement machine, observe the
order of switching on. If this is not observed, errors could occur (e.g. CAN switch error).
Always switch the waffle pack changer on before the SIPLACE placement machine.
In the event of an error, switch the waffle pack changer and the SIPLACE placement
machine off and then switch them back on again in the right order. Observe the re-
quired waiting periods.
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 6 Station extensions
From software version SC.713.1 Edition 12/2020 6.4 Waffle pack changer (WPC5/WPC6)
311
6.4.5 Technical data
6.4.5.1 Dimensions, weight
6
WPC5/WPC6 dimensions
Length x width
Height
For 900 mm PCB conveyor height
For 930 mm PCB conveyor height
For 950 mm PCB conveyor height
1520 mm x 360 mm
1430 mm
1460 mm
1480 mm
WPC5 weight
Basic configuration (with cassettes and waffle pack tray carriers)
Fully configured (with WPTC and cassette with components)
approx. 270 kg
approx. 320 kg
WPC6 weight
Basic configuration (with cassettes and waffle pack tray carriers)
Fully configured (with WPTC and cassette with components)
approx. 280 kg
approx. 330 kg
WPC5/WPC6 surface load 25 N/cm²
Weight of the waffle pack tray carrier 0.8 kg
Dimensions of waffle pack tray carrier (LxWxH) 360 mm x 260 mm x 6 mm
Dimensions of waffle pack tray (LxWxH) 347 mm x 235 mm x 15 mm
Height of waffle-pack tray, including component
Standard (all levels occupied)
WPC5
WPC6
High components (levels omitted)
WPC5
WPC6
High components
(with Very High Force TwinStar on request (VHF TH)
*a
WPC5
*b
WPC6
*b
15 mm
15 mm
29 mm
29 mm
45 mm
45 mm
Distance from level to level 17 mm (± 2 mm)
Storage capacity 28 waffle pack tray carriers
Changeover time for waffle-pack tray carriers
over 1 level
over 10 levels
over 27 levels
1.9 s
2.3 s
2.8 s
*)a From serial number B3xxx (WPC5) / C3xxx (WPC6)
*)b 45 mm refers to the feed axis (component height + height of waffle pack tray).
6 Station extensions Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
6.4 Waffle pack changer (WPC5/WPC6) From software version SC.713.1 Edition 12/2020
312
6.4.5.2 Electrical ratings
6
6.4.5.3 Permitted environmental factors
6
Supply voltage 3 x 200 V~ ± 5 %; 50/60 Hz (Japan)
3 x 208 V~ ± 5 %; 50/60 Hz (U.S.A)
3 x 230 V~ ± 5 %; 50/60 Hz
3 x 380 V~ ± 5 %; 50/60 Hz
3 x 400 V~ ± 5 %; 50/60 Hz (Europe)
3 x 415 V~ ± 5 %; 50/60 Hz
Nominal apparent power 1.5 kVA
Nominal active power 1.0 kW
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 - 75%
(no higher than 45% on average to prevent any possibility
of condensation on the waffle pack changer.)