200
4.2.3.6 Mains connection - mains connection cable WITHOUT plug (configuration 3)
The placement machine is supplied with an approx. 5m mains connection cable WITHOUT plug.
4
4
Fig. 4.2 - 6 Description of wires in the mains power cable
WARNING
The mains connection cable may only be connected by a qualified electrician.
The mains connection cable may only be connected by a qualified electrician. A qualified
electrician is a person with suitable professional qualifications, knowledge and experi-
ence, who is able to recognize hazards caused by electrical power and also prevent
these hazards from arising.
The regulations of the country in which the placement machine is operated apply.
1 = (L1): three-phase
2 = (L2): three-phase
3 = (L3): three-phase
4 = (N): neutral conductor
green/yellow = (PE): conductor
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 4 Setting up and commissioning
From software version SC.713.1 Edition 12/2020 4.2 Infrastructure at the installation location
201
4.2.3.7 Overview of the microfuses
4
Fig. 4.2 - 7 Overview of the microfuses
4
Fuse Components Electricity
[A]
Voltage [V]
F1 MGCU 1 6,3 27
F2 MGCU 2 6,3 27
F3 MGCU 3 6,3 27
F4 Distributor/power fail 6,3 24
F5 Station PC 6,3 27
F6 Options PC 6,3 27
4 Setting up and commissioning Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
4.2 Infrastructure at the installation location From software version SC.713.1 Edition 12/2020
202
4
F7 Conveyor control 6,3 24
F8 Y sensor module 1 6,3 27
F9 Y sensor module 2 6,3 27
F10 Internal 6,3 24
F11 SSK-Ready CSB 6,3 24
F12 CSB supply 6,3 24
F14 Head supply 1 6,3 42
F15 Head supply 2 6,3 42
F16 Conveyor drives 6,3 42
-- -- -- --
-- -- -- --
F19 Head axis 1 6,3 160
F20 Head axis 2 6,3 160
F21 Vision 6,3 42
F22 FCU 1 6,3 27
F23 FCU 2 6,3 27
PLEASE NOTE
Replacing the microfuses
Only replace the microfuses with approved fuse links!
Fuse Components Electricity
[A]
Voltage [V]