00198661-02_UM_SX12-V3_EN.pdf - 第234页

5 Tasks at the placement machine Instruction manual SIPLACE SX1/ SX2 Edition V2 and V3 5.2 Controls and displays From software version SC.713.1 Edition 12/2020 234 5.2.2 Overview of the SIPLACE SX1/SX2 V2 5 Fig. 5.2 - 2 …

100%1 / 366
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 5 Tasks at the placement machine
From software version SC.713.1 Edition 12/2020 5.2 Controls and displays
233
5.2 Controls and displays
5.2.1 Overview of the SIPLACE SX1/SX2 V3
5
Fig. 5.2 - 1 Controls and displays on the SIPLACE SX1/SX2 V3
5
(1) Main switch (5) Multitouch monitor
(2) Start button (white) (6) Indicator lamps with horn
(3) EMERGENCY STOP button (T) Direction of PCB transport
(4) Stop button (black)
(1)
(3)
(2)
(5)
(6)
(6)
(4)
5 Tasks at the placement machine Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
5.2 Controls and displays From software version SC.713.1 Edition 12/2020
234
5.2.2 Overview of the SIPLACE SX1/SX2 V2
5
Fig. 5.2 - 2 Controls and displays on the SIPLACE SX1/SX2 V2
5
(1) Main switch (5) Stop button (black)
(2) Start button (white) (6) LCD touchscreen
(3) EMERGENCY STOP button (7) Indicator lamps with horn
(4) Keyboard (T) Direction of PCB transport
(1)
(4)
(3)
(2)
(6)
(7)
(7)
(5)
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 5 Tasks at the placement machine
From software version SC.713.1 Edition 12/2020 5.2 Controls and displays
235
5.2.3 Controls on the placement machine's operator panels
All the controls can be reached by a 1.40 m tall person.
Main switch 5
The main power switch is used to switch the power supply to the placement machine on and off.
Stop button (black) 5
This black button is used to stop the placement process at the placement machine.
Start button (white) 5
This white button starts the placement machine after it has been switched on or after faults have
been eliminated.
EMERGENCY STOP button 5
The EMERGENCY STOP button latches in the ON position when pressed. The power supply to
the gantry axes, the component trolleys, conveyors and used tape cutters is interrupted and the
voltage supplied to the star axes of the placement heads is reduced. Turn the button to release it.
Multi-touch monitor (for the SIPLACE SX1/SX2 V3) 5
On each side of the placement machine, there is a flat screen with a highly sensitive "multi-touch"
surface (screen with multi-finger gesture recognition). Use the station software to show a key-
board for screen entries.
LCD monitor (for the SIPLACE SX1/SX2 V2) 5
There is a flat LCD screen with a touch-sensitive surface (touchscreen) on either side of the place-
ment machine.
DANGER
Lethal voltages!
Some parts inside the placement machine carry potentially lethal voltages - even when
switched off at the main power switch.