Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 4 Setting up and commissioning
From software version SC.713.1 Edition 12/2020 4.2 Infrastructure at the installation location
199
4.2.3.5 Mains connection - mains connection cable WITH plug (configuration 2)
The placement machine is supplied with an approx. 5 m mains connection cable WITH a CEE
plug, red 16 A (in accordance with IEC 60309).
4
4
Fig. 4.2 - 5 Assignment in the CEE plug
WARNING
The mains connection cable may only be connected by a qualified electrician.
The mains connection cable may only be connected by a qualified electrician. A qualified
electrician is a person with suitable professional qualifications, knowledge and experi-
ence, who is able to recognize hazards caused by electrical power and also prevent
these hazards from arising.
The regulations of the country in which the placement machine is operated apply.
PE
L1
L2
L3
N

4 Setting up and commissioning Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
4.2 Infrastructure at the installation location From software version SC.713.1 Edition 12/2020
200
4.2.3.6 Mains connection - mains connection cable WITHOUT plug (configuration 3)
The placement machine is supplied with an approx. 5m mains connection cable WITHOUT plug.
4
4
Fig. 4.2 - 6 Description of wires in the mains power cable
WARNING
The mains connection cable may only be connected by a qualified electrician.
The mains connection cable may only be connected by a qualified electrician. A qualified
electrician is a person with suitable professional qualifications, knowledge and experi-
ence, who is able to recognize hazards caused by electrical power and also prevent
these hazards from arising.
The regulations of the country in which the placement machine is operated apply.
1 = (L1): three-phase
2 = (L2): three-phase
3 = (L3): three-phase
4 = (N): neutral conductor
green/yellow = (PE): conductor

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 4 Setting up and commissioning
From software version SC.713.1 Edition 12/2020 4.2 Infrastructure at the installation location
201
4.2.3.7 Overview of the microfuses
4
Fig. 4.2 - 7 Overview of the microfuses
4
Fuse Components Electricity
[A]
Voltage [V]
F1 MGCU 1 6,3 27
F2 MGCU 2 6,3 27
F3 MGCU 3 6,3 27
F4 Distributor/power fail 6,3 24
F5 Station PC 6,3 27
F6 Options PC 6,3 27