00198661-02_UM_SX12-V3_EN.pdf - 第107页
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 3 Technical data and assemblies From software version SC.713.1 Edition 12/2 020 3.3 Component feed ing 107 3.3 Component feeding 3 3.4 Ambient conditions and connectio…

3 Technical data and assemblies Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
3.2 Performance data for the SIPLACE SX1/SX2 V2 From software version SC.713.1 Edition 12/2020
106
3.2.2 PCB conveyor - data
3
Single conveyor Flexible dual con-
veyor
Dual conveyor in single
conveyor mode
Standard dimensions
(length x width)
50 mm x 50 mm to
450 mm x 560 mm
50 mm x 50 mm to
450 mm x 260 mm
50 mm x 50 mm to
450 mm x 460 mm
Dimensions with “Long
Board”option
(length x width)
50 mm x 50 mm to
1525 mm
*a
x 560 mm
50 mm x 50 mm to
850 mm x 260 mm
50 mm x 50 mm to
850 mm x 460 mm
Stationary conveyor side Right, left or outer
Automatic electrical width adjust-
ment
Standard
PCB thickness
Standard
"Thick board" option
0.3 mm to 4.5 mm
2.0 mm to 6.5 mm
Clamping length of board 450 mm
Space for positioning support pins 440 mm
PCB warpage See page 151
PCB weight
*b
Standard Max. 3.0 kg Max. 2.0 kg Max. 2.0 kg
Clearance on PCB underside 25 mm
PCB conveyor height
Option
Standard
Option SMEMA
900 mm
930 mm
950 mm
Type of interface SMEMA or IPC-HERMES-9852
Component-free PCB handling
edge
3 mm
PCB changeover time
Single conveyor
Dual conveyor
*c
< 1.5 seconds
0 seconds
*)a With input/output conveyor only
*)b The board weight value refers to the weight of the board plus the weight of the components.
*)c 0 seconds in asynchronous mode, otherwise 1.5 seconds.

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 3 Technical data and assemblies
From software version SC.713.1 Edition 12/2020 3.3 Component feeding
107
3.3 Component feeding
3
3.4 Ambient conditions and connection values
3.4.1 Ambient conditions for packaging, transportation and storage
3
3.4.2 Ambient conditions for placement machine operation
3
Feeder locations
2 component trolleys with 60 tracks
2 component trolleys with 30 tracks
120 feeders with 8 mm each
60 feeders with 8 mm
Technical data
Tape reel diameter 178 mm to max. 483 mm diameter (7" - 19")
Component trolley changeover time < 1 minute
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75% (on average not higher than 45%, so that there is
no risk of condensation on the placement machine.)
Ambient pressure > 750 mbar (corresponds to 1700 m above mean sea level)

3 Technical data and assemblies Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
3.4 Ambient conditions and connection values From software version SC.713.1 Edition 12/2020
108
3.4.3 Compressed air supply and compressed air specification
3
3
Compressed air supply
Compressed air pressure values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection R 3/4" inner thread (pipe thread) with 1/2" hose connection
Compressed air consumption
*a
Placement head configura-
tion
Compressed air
consumption
with vacuum pumpd
*b
Compressed air
consumption
without vacuum pump
*c
SIPLACE SX2
SIPLACE SX1
C&P20 P2 / C&P20 P2
C&P20 P / C&P20 P
CPP / CPP
CPP / TH
TH / TH
C&P20 P2
C&P20 P
CPP
TH
200 Nl/min
200 Nl/min
--
--
--
100 Nl/min
100 Nl/min
--
--
490 Nl/min
490 Nl/min
240 Nl/min
240 Nl/min
200 Nl/min
280 Nl/min
280 Nl/min
140 Nl/min
100 Nl/min
Compressed air specification according to ISO 8573
Particle size (ISO class 3) 5 µm
Particle density (ISO class 3) 5 mg/m³
Maximum oil content
(ISO class 1)
Particle density 0.01 mg/
m³
Pressure dewpoint (ISO class 4) Dewpoint + 3°
*)a Average consumption values. Under normal atmospheric conditions at 20°C and 1013 hPa
*)b Vacuum pump only for the C&P20 P2 or the C&P20 P.
*)c Standard