00198661-02_UM_SX12-V3_EN.pdf - 第267页
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 5 Tasks at the placement machine From software version SC.713.1 Edition 12/2020 5.10 Setting up th e feeder modules 267 On standby , the status display (item 2 in fig.…

5 Tasks at the placement machine Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
5.10 Setting up the feeder modules From software version SC.713.1 Edition 12/2020
266
5.10 Setting up the feeder modules
5.10.1 Notes on handling feeder modules
Feeder modules are precision devices. You should therefore handle the feeder modules with care.
Avoid bumping feeder modules into obstacles.
Do not drop the feeder modules.
Always use suitable tools for preventive maintenance.
5.10.2 Removing X feeder modules from the changeover table
5
Fig. 5.10 - 1 Removing X feeder modules from the changeover table
(1) Removal handle
(2) Status display
(3) LED display
(4) Rail for checking height of feeder
(5) Latch for locking the feeder modules
(6) Centering rail
5
(2)
(1)
(4)
(5)
(6)
(3)

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 5 Tasks at the placement machine
From software version SC.713.1 Edition 12/2020 5.10 Setting up the feeder modules
267
On standby, the status display (item 2 in fig. 5.10 - 1
, page 266) lights up green if the X axis feeder
module is contained in the current setup. If the feeder module is not contained in the current setup,
the status display remains off.
The feeder module is locked in position in the changeover table by a latch, and cannot be pulled
out. The procedure for removing feeder modules from the changeover table is as follows:
Press the removal handle (item 1 in fig. 5.10 - 1, page 266). The removal handle jumps out
and the status display goes out.
Wait approximately 1 second until the lock (item 4 in fig. 5.10 - 1, page 266) releases the
feeder module.
Use the removal handle to pull the feeder module out of the changeover table. If you wait lon-
ger than 5 seconds, the feeder module will be locked once more. The status display will shine
red.
Engage the removal handle once more. If the feeder module is contained in the current setup,
the status display lights up green and the track number and increment will appear on the LCD
display once more.

5 Tasks at the placement machine Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
5.10 Setting up the feeder modules From software version SC.713.1 Edition 12/2020
268
5.10.3 Using the X feeder module
5.10.3.1 Check the X feeder module before using it
Check the following points before you use a feeder module on the changeover table:
The feeder module must be in perfect condition.
Tap the cover foil rocker (item 2 in fig. 5.10 - 2, page 269) lightly to make sure that it has not
jammed.
Check that the area around the pickup window (item 3 in fig. 5.10 - 2, page 269) is free
from loose components.
5
5
Press the lever (item 4 in fig. 5.10 - 2, page 269) forward slightly to open the pickup window
(item 3 in fig. 5.10 - 2
, page 269). This will raise the pick-up window slightly.
5
Remove any loose components from beneath the pick-up window.
Close the pickup window (item 3 in fig. 5.10 - 2, page 269), by returning the lever (item 4 in
fig. 5.10 - 2
, page269).
Remove loose components from the changeover table with a brush or use a vacuum cleaner
with appropriate nozzle.
5
PLEASE NOTE
Empty the component disposal compartment (item 5 in fig.5.10 - 2, page 269), be-
fore you
shake components out of the feeder module.
PLEASE NOTE
The tensioned cover foil continues to transport the tape when the tape has been inserted
and exposes the components.
Do not press the lever (item 4 in fig. 5.10 - 2, page 269) if a tape is inserted.
PLEASE NOTE
If the component tape is already inserted, cut it off flush with the front edge of the
feeder module. There should still be 2 holes visible in the perforation.