00198661-02_UM_SX12-V3_EN.pdf - 第193页

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 4 Setting up and commissioning From software version SC.713.1 Edition 12/2020 4.2 Infrastructure at the in stallation location 193 4.2.2.2 Compressed air connection on…

100%1 / 366
4 Setting up and commissioning Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
4.2 Infrastructure at the installation location From software version SC.713.1 Edition 12/2020
192
4.2.2 Compressed air supply
4
Fig. 4.2 - 1 Position of compressed air supply in the placement machine
(1) Installation position of compressed air supply
4.2.2.1 Checking the compressed air supply
Check whether the compressed air supply complies with the prescribed machine specifications
(see table in section 3.4
, page 107).
Record the compressed air characteristics at the installation location.
4
(1)
WARNING
Risk of injuries!
Risk of injuries from pressurized compressed air lines.
NEVER detach compressed air lines while they are still pressurized.
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 4 Setting up and commissioning
From software version SC.713.1 Edition 12/2020 4.2 Infrastructure at the installation location
193
4.2.2.2 Compressed air connection on the placement machine
4
Fig. 4.2 - 2 Compressed air unit on the placement machine
Legend for fig.4.2 - 2
(1) Manometer for supply pressure of gantries 1 and 2
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(2) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(3) Manometer for the bulkcase feeder module supply pressure
Target pressure: 0.25 ± 0.05 MPa, 2.5 ± 0.5 bar (display range: 0 - 0.6 MPa, 0 - 6 bar)
(4) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(5) Compressed air filter
(6) Compressed air connection
(7) Stop valve in the "OPEN" position
(6)
(1)
(2)
(3)
(4)
(5)
(7)
4 Setting up and commissioning Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
4.2 Infrastructure at the installation location From software version SC.713.1 Edition 12/2020
194
4.2.3 Main power supply
4
Fig. 4.2 - 3 Position of power supply in the placement machine
(1) Lock
(2) Main power switch secured to prevent switching on again
(3) Power supply unit behind the cover
4.2.3.1 Danger notes
4
(1)
(2)
(3)
DANGER
Dangerous voltage levels!
The placement machine is supplied with 3 x 380 V~ to 3 x 415 V ± 10 %, 50/60 Hz or op-
tionally with
3 x 200 V~ to 3 x 220 V~ ± 10 %; 50/60 Hz mains voltage. This means that some parts of
the system carry potentially lethal voltages - even when switched off at the main power
switch and with disconnected mains plug.
Incorrect handling of this placement machine can therefore result in death or severe injury
or considerable damage to equipment.
Always follow the applicable accident prevention and DIN regulations (particularly EN
60204, part 1 or IEC 60204, part 1) and the applicable regulations in your own coun-
try.
The covers over the power supply unit may ONLY be opened by appropriately quali-
fied and trained personnel.