2
2.1.3.3 Safety of plant and equipment
Never make changes, however minor, unless you are totally aware of the effect they will have
on the overall functioning of the system.
The stations must always be set up, retooled and maintained by appropriately trained person-
nel.
Do not make modifications to the safety equipment. In particular, NEVER deactivate circuit-
breakers or remove safety devices.
2.1.4 Safety instructions for laser units
Permission to operate components that are classified as lasers is withdrawn if
– Mechanical damage to the unit is observed, or
– Any work is done on the mechanical or electrical parts of the unit. Even damaged or miss-
ing screw locking paint on laser components (e.g. cover plates, fasteners, adjusting po-
tentiometer) counts as work.
– Only ASM Assembly Systems GmbH&Co.KG service engineers or the machine owner's
service engineers, who have been trained by ASM, may replace laser components.
– Repairs to laser assemblies may only be performed by ASM Assembly Systems
GmbH&Co.KG at their factory.
WARNING
Dangerous voltage levels!
The placement machines are operated electrically. Certain parts are still live when the
main power switch is off and the mains plug has been disconnected. Switch off the main
switch, secure to prevent switching on, disconnect the mains plug and wait for 5 minutes.
There is a risk of death, severe injury and/or considerable damage to equipment if these
instructions are not followed.
Switch off at the main switch and disconnect the placement machine from the power
supply before carrying out any work on live components.
Test to check that there is no remaining voltage supply. See the procedure described
in the service manual.
Lock the placement machine as described in section 2.9, page 97.

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 2 Operational safety
From software version SC.713.1 Edition 12/2020 2.1 Safety instructions
35
2.1.5 Safety instructions on permanent magnets
Powerful permanent magnets are used for the linear motors of the X and Y axes.
2
2
2
2
DANGER
Risk to life from powerful magnetic fields caused by the permanent magnets inside the
placement machine
When protective covers are opened inside the placement machine, the life of persons
with the following passive or active implants is put at risk:
– Pacemakers
– Defibrillators
– Insulin pumps etc.
At-risk people may not stand in the immediate vicinity of the placement machine.
WARNING
DANGER OF CRUSHING!
There is a danger of crushing for persons with passive metal implants (e.g. plates,
screws).
Never reach into the placement machine when the protective covers are open and
do not bend over the open placement machine.
Do not bring any metal objects into the danger area.
CAUTION
Data loss due to powerful magnetic fields!
There is a risk that the powerful magnetic fields could corrupt data on data media or credit
cards and check cards.
Keep data carriers and check cards away from the placement machine.

2 Operational safety Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
2.1 Safety instructions From software version SC.713.1 Edition 12/2020
36
Fig. 2.1 - 1 Position of the permanent magnets for the linear drives
(1) Permanent magnets for X linear motors on gantry 2
(2) Permanent magnets for Y linear motors on gantry 1 and gantry 2 (for loose or fixed bearing)
(3) Permanent magnets for X linear motors on gantry 1
(4) Permanent magnets for Y linear motors on gantry 1 and gantry 2 (for loose or fixed bearing)
(T) Direction of PCB transport
Please note the following points when working on the permanent magnets:
People with active implants (e.g. heart pacemakers) or other ferromagnetic prostheses are
expressly prohibited from working on or coming near these devices. Always keep a safe dis-